23
PROGRAMMING
AUTO MODE (LOW HUMIDITY TRIGGER)
Pressing the up or down button sets the low
humidity trigger. The devices will activate if the
probe’s reading meets or falls below this threshold.
Once triggered, the devices will gradually ramp up
to the level set in ON mode. If the probe’s reading
rises above this trigger point, the devices will
gradually slow down to a stop or at the level set in
OFF Mode.
You may set this trigger above the high humidity
trigger to create a range in which the devices
are active.
AUTO MODE (HIGH HUMIDITY TRIGGER)
Pressing the up or down button sets the high
humidity trigger. The devices will activate if the
probe’s reading meets or exceeds this threshold.
Once triggered, the devices will gradually ramp up
to the level set in ON mode. If the probe’s reading
falls below this trigger point, the devices will
gradually slow down to a stop or at the level set in
OFF mode.
You may set this trigger below the low humidity
trigger to create a specific range in which the
devices are active.
Any of the four trigger points can activate while
you are in AUTO Mode, even if you are viewing
another trigger point. Please set a trigger point
to OFF if not in use, by holding down the up and
down button.
If there is a level set in OFF Mode other than zero,
the devices will run at that level when triggered
to turn off.
Any of the four trigger points can activate while
you are in AUTO Mode, even if you are viewing
another trigger point. Please set a trigger point
to OFF if not in use, by holding down the up and
down button.
If there is a level set in OFF Mode other than zero,
the devices will run at that level when triggered
to turn off.