TRANSITION HUMIDITY SETTING
Adjusts the transition threshold between the levels in
the AUTO Mode humidity triggers.
Press the up or down button to cycle through 0% to
8% to set a transition threshold. The level will be set
one level above the OFF Mode level when the sensor
humidity first meets or exceeds the high humidity
trigger. For every transition threshold crossed, the
level will ramp up by one level, up until it reaches the
level set in ON Mode.
In this example, your high humidity trigger is set at
67%, the OFF Mode level is 2, and the ON Mode
level is 7. If the transition threshold is set to 0%, then
the devices will trigger to run at level 7 when the
sensor humidity meets or exceeds 67%. However,
if the transition threshold is set to 5%, then the fan
will trigger to run at level 3 when it meets or exceeds
67%. It will then step up to level 4 when meeting or
exceeding 72%, level 5 at 77%, and level 6 at 82%.
From 87% on, it will run at level 7, the level set in ON
Mode.
PROGRAMMING