9006-15 Room thermostat with batteries
AC-FIX
– V1.1_20121102
AC-FIX 2012 11.02
Advanced setting (qualified person preferred)
Usually finished at mounting thermostat.
Press menu key simultaneously switching on the thermostat to enter advanced setting.
1ADJ: Temperature calibration.
Press + or
– key to adjust present checked value.
Adjustable scale: ± 9.9 ºC.
Re-press menu key to enter next advanced setting step.
2DIT: Switch differential setting.
Press + or
– key to change switch differential
Setting range: 0.5 ~ 5.0ºC
Re-press menu key to enter next advanced setting step.
3LTP: Start anti-frozen function in power off.
Press + or
– key to change the present anti-frozen state.
Re-press menu key to enter next advanced setting step.
4PRG: Open / close programme and clock function.
Press + or
– key to open/close the programme and clock function.
Re-press menu key to enter next advanced setting step.
5COD: Start to check code.
Press + or
– key to start check code with receiver
Re-press menu key to enter next advanced setting step.
6PA: Wireless frequency power choosing.
Press + or
– key to modify the wireless frequency power.
Setting range: 0~3, 0 Min, 3 Max.
Re-press menu key to enter next advanced setting step.
Reset to factory setting.
Press
key for 5 seconds till display
– reset to factory setting.
Re-press menu key to enter next advanced setting step.
Press Off key to quit advanced setting for saving.