9006-15 Room thermostat with batteries 

     

     AC-FIX 

– V1.1_20121102  

 

AC-FIX 2012  11.02

 

Three control modes:  

Manual temperature control, periods programming control, anti-frozen protection control. 
 

Manual  temperature  control:  thermostat  will  control  room  temperature  according  to  current  set 
temperature value, it has nothing to do with time (event). 

 

Event  programming  control:  24  event  for  24  hours  each  day,  every  single  event  can  be  set  as 
energy  saving  temperature  or  comfort  temperature,  which  can  set  event  and  temperature 
according  to  individual  habits.  Event  programming  control  is  circulated  by  7  days,  so  it  is  called 
weekly programming control. 
 
Anti-frozen function: set temperature is 5ºC to ensure room temperature is not lower than 5ºC to 
avoid  frozen  caused  by  low  temperature  (only  used  in  water-based  heating).  When  used  in 
electric cable  heating  please  close  this  function  in  advanced  setting.  Factory  setting:  anti-frozen 
function usual closed, if necessary, please modify it in advanced setting. 

 

Simple operation steps:  
 
 

On/Off: 

 

Press on/off key to choose on/off. 

 

Switch on: display the full screen firstly, then recover to last work mode before switch off. 
Switch  off:  display  OFF.  If  has  anti-frozen  protection  function,  it  will  enter  anti-frozen 
mode automatically when switch off, symbol as following: 

 

 

Press this key can change manual mode and programming mode. For example:  

                            

 

      Manual mode             Programmed mode

 

 

 

Setting value decrease key (-). 

 

Press this key one time will enter to manual mode to adjust temperature value. 

 

Press once again, setting value will decrease 0.5ºC every step. 

 

Press this key above 3 seconds, the value will be decreased by 0.5ºC step in quickly.

 

 
 

Setting value increase key (+). 

 

Press this key one time will enter to manual mode to adjust temperature value. 
Press once again, setting value will increase 0.5ºC every step. 
Press this key above 3 seconds, the value will be increased by 0.5ºC step in quickly 
Adjust date and clock: 
Press this key for 5 seconds till date symbol twinkles, press + or 

– key to adjust date 

Press this key one time, hour symbol twinkles, press + or 

– key to adjust current hour. 

Press this key on time, minute symbol twinkles, press + or 

– key to adjust current minute. 

Please adjust date and clock after replacing the batteries. 

 

 

 

Key-lock function

 

 

Key-lock  mode:  press  any  key  that  will  be  invalid  when  key  locked  this  function  avoid  children  or    

           unprofessional person to modify setting value of controller. 

 

Key lock: press + and 

– key simultaneously till display 

 symbol 

 

Key unlock: press + and 

– key simultaneously till display 

 symbol 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 
 

 

 
 

 

 

 

 

 

 

 

 

Summary of Contents for 9006-15

Page 1: ...oor heating or boiler heating 2 pieces size AA batteries to ensure the power of one heating season Adopt magnetic latching relay low power consumption 24 events every day 7 day programmable controller...

Page 2: ...9006 15 1 red 9006 15 1 ivory 9006 15 1 baking silver black blue red ivory baking silver potential free output Max 5A 9006 15 ivory 9006 15 silver ivory silver 433MHz wireless frequency output Symbol...

Page 3: ...lay OFF If has anti frozen protection function it will enter anti frozen mode automatically when switch off symbol as following Press this key can change manual mode and programming mode For example M...

Page 4: ...nction in power off Press or key to change the present anti frozen state Re press menu key to enter next advanced setting step 4PRG Open close programme and clock function Press or key to open close t...

Page 5: ...g of clock programming control we advice to choose more suitable programming when in using Used in residential place which can meet to comfortable and energy saving effect Monday to Friday are work da...

Page 6: ...mme 3 Press menu key again to choose programme date number 4 Press key to enter anti frozen mode and programme mode for change 5 The temperature sensor symbol change to 0 24 hour event in programme mo...

Page 7: ...with batteries AC FIX V1 1_20121102 AC FIX 2012 11 02 Application II Apply to 9006 15 thermostat wireless mode Application III 9006 15 wireless thermostat many to one which applies to temperature con...

Page 8: ...9006 15 Room thermostat with batteries AC FIX V1 1_20121102 AC FIX 2012 11 02 Mounting...

Reviews: