background image

9006-15 Room thermostat with batteries 

     

     AC-FIX 

– V1.1_20121102  

 

AC-FIX 2012  11.02

 

Parameter   

 

 

 

 

 

Dimensions (mm): 

 

Power supply: DC3V, 2 pieces size AA batteries 
Wireless frequency: 433MHz 
Measuring range: 0 ~ 95ºC 
Setting range: 5 ~ 90ºC 
Switching differential: 0.5 ~ 5ºC adjustable (factory setting: 1ºC) 
Sensor: internal NTC sensor 
Measuring quantity: 1 pcs 
Potential free output: Max5A (AC220V resistance load) 

 

Selection table 

 

 

 

Model 

color 

output 

9006-15(1) (black) 
9006-15(1) (blue) 
9006-15(1) (red) 
9006-15(1) (ivory) 
9006-15(1) (baking silver) 

black 

blue 

red 

ivory 

baking silver 

 
 
potential free output Max.5A 

9006-15 (ivory) 
9006-15 (silver) 

ivory 

silver 

433MHz wireless frequency output 

 

Symbol explaining 
 

 

 

 

 

 

 

 

 

 

 

Simple touching key, large LCD screen with white backlight

 

Touching keys:

 

Menu   Mode/clock         On/Off      Decrease   Increase

 

24-hour events, energy saving and comfort mode display. 
0 ~ 24 number is for 24 hours each day. 
In energy saving (low temperature) event. 
In comfort (high temperature) event. 
Weekly programming 7 days for one week. 
Shows Monday to Sunday. 

Control mode: 

Programming mode, 

Manual mode, 

Anti-frozen mode 

Symbol: 

Low batteries 

Key-lock 

Heating 

Summary of Contents for 9006-15

Page 1: ...oor heating or boiler heating 2 pieces size AA batteries to ensure the power of one heating season Adopt magnetic latching relay low power consumption 24 events every day 7 day programmable controller...

Page 2: ...9006 15 1 red 9006 15 1 ivory 9006 15 1 baking silver black blue red ivory baking silver potential free output Max 5A 9006 15 ivory 9006 15 silver ivory silver 433MHz wireless frequency output Symbol...

Page 3: ...lay OFF If has anti frozen protection function it will enter anti frozen mode automatically when switch off symbol as following Press this key can change manual mode and programming mode For example M...

Page 4: ...nction in power off Press or key to change the present anti frozen state Re press menu key to enter next advanced setting step 4PRG Open close programme and clock function Press or key to open close t...

Page 5: ...g of clock programming control we advice to choose more suitable programming when in using Used in residential place which can meet to comfortable and energy saving effect Monday to Friday are work da...

Page 6: ...mme 3 Press menu key again to choose programme date number 4 Press key to enter anti frozen mode and programme mode for change 5 The temperature sensor symbol change to 0 24 hour event in programme mo...

Page 7: ...with batteries AC FIX V1 1_20121102 AC FIX 2012 11 02 Application II Apply to 9006 15 thermostat wireless mode Application III 9006 15 wireless thermostat many to one which applies to temperature con...

Page 8: ...9006 15 Room thermostat with batteries AC FIX V1 1_20121102 AC FIX 2012 11 02 Mounting...

Reviews: