11
English
3.2. Installation
ATTENTION!
The installation of the device involves work on the mains
voltage. It must therefore be carried out by a specialist in
accordance with the usual national installation regulations and
connection conditions. During installation, the electrical line to be
connected must be de-energized. Therefore, first switch off the
power.
Make absolutely sure that the circuit breaker remains switched
off during the entire installation. If possible, ensure that this
circuit breaker is not accessible. Subsequently, determine the
absence of voltage at all poles using a suitable measuring
device.
Using the drilling template, mark the position of the required drill
holes, drill the holes and insert the dowels.
Three small openings are indicated on the back of the camera
base, for the three wires of the power cable that are to supply
the camera with regular voltage. Feed the three wires through
the rubber seal at the corresponding points. Ensure the
appropriate cable length for the following connection to the luster
terminal in the base of the mount. Mount the base of the bracket
at the intended camera position using the enclosed screws.
Connect the live conductor previously passed through the foot,
neutral conductor and the protective conductor with the luster
terminal.
Tip: The luster terminal can be removed from its holder.
L = Current carrying conductor (mostly black or brown)
N = neutral conductor (mostly blue)
PE= protective conductor (green-yellow)