background image

 

English 

Introduction 

 

Dear customer, dear customer, 

we are pleased that you have decided to use our product and thank you for your trust! You have made 
a good choice. 

This motion detector (hereinafter referred to as "device") has been developed and manufactured with 
the greatest care. Please read these operating instructions in full and observe all operating and safety 
instructions, as this ensures the best possible handling of the device.  This document is regarded as 
assembly and maintenance instructions. 

 

ABUS  Security-Center  hereby  declares  that  the  enclosed  product  complies  with  the  following 
guidelines concerning the product: 

 

RED  Directive  2014/53/EU,  EMC  Directive  2014/30/EU,  Low  Voltage  Directive  2014/35/EU,  RoHS 
Directive  2011/65/EU.  The  full  text  of  the  EU  Declaration  of  Conformity  is  available  at  the  following 
Internet address 

www.abus.com/product/PLBW10100

 

It can also be obtained from the following address: 

ABUS Security Center GmbH & Co KG, 

Left Kreuthweg 5, 86444 Affing, GERMANY 

 

 

 

 

If you have any questions or suggestions, please contact our customer service: 

Mail:    

 

 

ABUS Support, Linker Kreuthweg 5, 86444 Affing, Germany 

E-mail:  

 

 

[email protected]

 

Phone:  

 

 

+49 8207 959 90 0 

Opening hours hotline:  

Mon-Thu: 08 - 17 h; Fri: 08 - 14 h 

 
 
 
 
 
 
 
All contained company names and product names are trademarks of their respective owners. All rights 
reserved. 

 

 

Disclaimer 

This operating manual has been prepared with the utmost care. Should you nevertheless notice any 
omissions or inaccuracies, please notify us in writing at the address given above. 

Your rights are limited to the repair or replacement of this product in the condition as delivered. ABUS 
Security Center assumes no liability for any special, incidental or consequential damages, including 
but not limited to loss of revenue, loss of profits, restrictions in the use of the software, loss or recovery 
of data, cost of replacement equipment, downtime, property damage and claims by third parties, as 
a result of, among other things, the followinga. contractual, statutory or damage compensation claims 
arising from the warranty, irrespective of other limited warranty provisions or those implied by law or 
in the event that the limited warranty does not apply, the scope of liability of ABUS Security Center is 
limited to the purchase price of the product. 

The contents of this manual may be changed without prior notice. 

© ABUS Security Center GmbH & Co KG, 09/2019 

Summary of Contents for PLBW10100

Page 1: ...PLBW10100 Nexello Motion Detector Important information and FAQs about this product and other products can be found on the website www abus com Manual version 1 2 Firmware version 1 58...

Page 2: ...reuthweg 5 86444 Affing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 h Fri 08 14 h All contained company names and product names are trademarks of thei...

Page 3: ...excessive dust For exact specifications check the technical data of the individual units Ensure that there is always sufficient ventilation that no direct heat sources act on the unit that no direct...

Page 4: ...cleaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use...

Page 5: ...rview 8 2 1 Inclusion teach in device 8 2 2 Planning assembly and installation 9 2 3 Exclusion teach out device 11 2 4 Resetting to factory settings 12 2 5 Wake up Waking up the device 12 2 6 Behaviou...

Page 6: ...ignation Comment A Front cover Slided onto the holder B Fresnel Lens For motion detection C LED indicator Status display for various processes Inclusion exclusion reset error D Link Button Manual trig...

Page 7: ...error tolerance on measured values we recommend using the light values only to distinguish between day and night Tamper protection between the device and wall bracket When the housing is opened the s...

Page 8: ...r does not support SmartStart follow these instructions for Product Classic Inclusion Activate the inclusion mode teach in mode on the Z Wave controller for more details please refer to the Z Wave con...

Page 9: ...set to 5 seconds each motion alarm is acknowledged after 5 seconds but to send a new motion alarm the motion detector must not have detected any motion for 5 seconds Use the test mode to select the o...

Page 10: ...8m range and 80 angle of detection Use the bracket as a template to mark the position of two drill holes on the wall There are two markings each for wall and corner mounting Fix the bracket to the wal...

Page 11: ...n Remove Exclusion in your Z Wave app and follow the instructions to set the Z Wave controller to Exclusion mode Press the Link button 3 times quickly within 1 5 seconds to start the exclusion on the...

Page 12: ...ease use this procedure only if the primary network controller is missing or otherwise not functional If the device is set to factory default the status is set to not included and the association sett...

Page 13: ...Only when the waiting time has elapsed without motion detection will the detector acknowledge the motion alarm and thus be able to send a motion alarm when a new motion is detected The standard waitin...

Page 14: ...Group 1 5 Lifeline General notification report battery report Device Reset Locally Notification Sensor Multilevel Report Group 2 5 on off control Notification basic set Group 1 Association Z Wave Con...

Page 15: ...Battery alarm replace soon 0x08 0x0A 0x00 Battery alarm replace now 0x08 0x0B 0x00 Battery alarm acknowledgement 0x08 0x00 0x01 0x0A 0x0B Light alarm day 0x14 0x01 0x00 Light alarm night 0x14 0x00 0x...

Page 16: ...1 13 2 Waiting time between two motion alarms 60 Waiting time from one motion alarm to the next triggering Adjustable from 5 15300 in seconds Hexadecimal 0x05 0x3BC4 14 1 BASIC SET to association grou...

Page 17: ...d classes Command class Version Association Version 2 Association Group Info Version 3 Battery Version 1 Configuration Version 4 Device Reset Locally Version 1 Firmware Update Md Version 5 Indicator V...

Page 18: ...e of battery 1x CR123A Battery life 3 years Sabotage protection Yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0002 Z Wave Device ID 0x0007 Z Wave SmartStart su...