background image

 

17 

English 

18 

Light values after 

movement alarm 

Defines which additional reports are to be sent 
in the event of a movement alarm. 

 

1 = Sensor multilevel report (LUX) 

 

2 = Light alarm report is sent 

 

3 = Lux and light alarm report is sent. 

(Hexadecimal: 0x0 - 0x03) 

19 

Threshold value for 

light alarm report  

50 

Threshold value from which LUX value the light 
alarm (day) is sent.  

 

Adjustable from 0 - 500 in lux 

 

 

 

3.5.  Supported command classes 

Command class 

Version 

Association 

Version 2 

Association Group Info 

Version 3 

Battery 

Version 1 

Configuration 

Version 4 

Device Reset Locally 

Version 1 

Firmware Update Md 

Version 5 

Indicator 

Version 3 

manufacturer specific 

Version 2 

Multi Channel Association 

Version 3 

Notification 

Version 8 

Power level 

Version 1 

Security 

Version 1 

Security 2 

Version 1 

Sensor Multilevel 

Version 5 

Supervision 

Version 1 

Transport Service 

Version 2 

Version 

Version 3 

wake up 

Version 2 

Z-Wave Plus Info 

Version 2 

 

3.6.  Supported security levels 

 

Security S2 Authenticated 

 

Security S2 Unauthenticated 

 

Security S0 Authenticated 

 

 

 

 

Summary of Contents for PLBW10100

Page 1: ...PLBW10100 Nexello Motion Detector Important information and FAQs about this product and other products can be found on the website www abus com Manual version 1 2 Firmware version 1 58...

Page 2: ...reuthweg 5 86444 Affing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 h Fri 08 14 h All contained company names and product names are trademarks of thei...

Page 3: ...excessive dust For exact specifications check the technical data of the individual units Ensure that there is always sufficient ventilation that no direct heat sources act on the unit that no direct...

Page 4: ...cleaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use...

Page 5: ...rview 8 2 1 Inclusion teach in device 8 2 2 Planning assembly and installation 9 2 3 Exclusion teach out device 11 2 4 Resetting to factory settings 12 2 5 Wake up Waking up the device 12 2 6 Behaviou...

Page 6: ...ignation Comment A Front cover Slided onto the holder B Fresnel Lens For motion detection C LED indicator Status display for various processes Inclusion exclusion reset error D Link Button Manual trig...

Page 7: ...error tolerance on measured values we recommend using the light values only to distinguish between day and night Tamper protection between the device and wall bracket When the housing is opened the s...

Page 8: ...r does not support SmartStart follow these instructions for Product Classic Inclusion Activate the inclusion mode teach in mode on the Z Wave controller for more details please refer to the Z Wave con...

Page 9: ...set to 5 seconds each motion alarm is acknowledged after 5 seconds but to send a new motion alarm the motion detector must not have detected any motion for 5 seconds Use the test mode to select the o...

Page 10: ...8m range and 80 angle of detection Use the bracket as a template to mark the position of two drill holes on the wall There are two markings each for wall and corner mounting Fix the bracket to the wal...

Page 11: ...n Remove Exclusion in your Z Wave app and follow the instructions to set the Z Wave controller to Exclusion mode Press the Link button 3 times quickly within 1 5 seconds to start the exclusion on the...

Page 12: ...ease use this procedure only if the primary network controller is missing or otherwise not functional If the device is set to factory default the status is set to not included and the association sett...

Page 13: ...Only when the waiting time has elapsed without motion detection will the detector acknowledge the motion alarm and thus be able to send a motion alarm when a new motion is detected The standard waitin...

Page 14: ...Group 1 5 Lifeline General notification report battery report Device Reset Locally Notification Sensor Multilevel Report Group 2 5 on off control Notification basic set Group 1 Association Z Wave Con...

Page 15: ...Battery alarm replace soon 0x08 0x0A 0x00 Battery alarm replace now 0x08 0x0B 0x00 Battery alarm acknowledgement 0x08 0x00 0x01 0x0A 0x0B Light alarm day 0x14 0x01 0x00 Light alarm night 0x14 0x00 0x...

Page 16: ...1 13 2 Waiting time between two motion alarms 60 Waiting time from one motion alarm to the next triggering Adjustable from 5 15300 in seconds Hexadecimal 0x05 0x3BC4 14 1 BASIC SET to association grou...

Page 17: ...d classes Command class Version Association Version 2 Association Group Info Version 3 Battery Version 1 Configuration Version 4 Device Reset Locally Version 1 Firmware Update Md Version 5 Indicator V...

Page 18: ...e of battery 1x CR123A Battery life 3 years Sabotage protection Yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0002 Z Wave Device ID 0x0007 Z Wave SmartStart su...

Reviews: