16
English
3.3. Reports
Notification report
Event
Type
Attribute
Parameter Length
Event Parameters
Opening alarm
(door / window open)
0x06
0x16
Opening alarm
Acknowledgement
(door / window closed)
0x06
0x17
Sabotage alarm
0x07
0x03
0x00
Sabotage alarm
acknowledgement
0x07
0x00
0x01
0x03
Battery alarm (replace soon)
0x08
0x0A
0x00
Battery alarm (replace now)
0x08
0x0B
0x00
Battery alarm
acknowledgement
0x08
0x00
0x01
0x0A / 0x0B
Battery report
Value
Description
0x05 - 0x64
(5
– 100)
Battery charge level in percent (%)
0xFF
(256)
Low battery
Central Scene Report
Sent when the bypass button is pressed
Event
Attribute
Key number
Press 1x briefly
0x00
0x01
Release (press and hold for a long time)
0x01
0x01
Press and hold (longer than 1s)
0x02
0x01
Press 2x briefly
0x03
0x01