5.5
Selecting the channel property (Permanent or Impulse)
Depending on the trained components, the corresponding channel
must be assigned either the “Permanent” or “Impulse” property.
Proceed as follows to do this:
In the main programming menu, select item 3 (LED 3 lights up).
Confirm by pressing SET. A double tone sounds.
Select the desired channel with SELECT and confirm by pressing
SET. A double tone sounds and the current channel property can
be determined according to the LED. A lit LED indicates
“Permanent” and a flashing LED indicates “Impulse”. You can now
switch between both modes using SELECT and confirm by
pressing SET. A double tone sounds and menu 3 is accessed
again.
Note: The following table gives an overview of which components
must be set to “Permanent” and which to “Impulse”:
Permanent Impulse
FU59xx, FU8100, FU8130, FU8140,
FU8150, FU832x, FU8330, FU8370,
FU841x, FU842x, FU843x
FU8300, FU8305, FU8310,
FU8340, FU8350, FU8360,
FU8380, FU8390
Example:
Magnetic contact FU8320W – Permanent
Detector open: Detector sends alarm
Detector closed: Detectors sends reset alarm
For “permanent” setting the detector resets the alarm to default
status by itself. This setting is necessary to all mentioned detectors
in column “Permanent”.
Panic Alarm button FU8300 – Impuls
Panic button pressed: Detector sends alarms
Panic button not pressed: No reset command is send (from
Detector).
For “Impuls” setting the IP-Alarm module sets the reset command
after 10 seconds by itself. This setting is necessary to all
mentioned detectors in column “Impuls”.
Summary of Contents for CASA10010
Page 2: ...2 IP Alarmmodul Installationsanleitung CASA10010 12036689 ...
Page 7: ...7 3 3 Platine RJ 45 17 ...
Page 27: ...27 IP Alarm Module Installation Instructions CASA10010 12036689 ...
Page 32: ...32 3 3 PCB RJ 45 17 ...
Page 51: ...51 Module d alarme IP Instructions d installation CASA10010 12036689 ...
Page 56: ...56 3 3 Platine RJ 45 17 ...
Page 76: ...76 IP alarmmodule Installatie instructies CASA10010 12036689 ...
Page 81: ...81 3 3 Printplaat RJ 45 17 ...
Page 100: ...100 IP alarmmodul Installationsvejledning CASA10010 12036689 ...
Page 105: ...105 3 3 Printkort RJ 45 17 ...