23
•
Auto - Automatic chroma error detection and correction. Use this setting when you don’t know
if a source has a Cue problem. also use this setting for all digital sources which use MpeG2
decoders (DVD players, digital satellite receivers, and so on.) as it will also detect and correct
chroma errors created by all sources of this type when the source is encoded as interlaced
(also sometimes called Interlaced Chroma Problem, or ICP).
Configuration
Test Patterns
The iscan Vp30 has 27 internal test patterns to assist in the setup of your individual sources and your
display. To learn more about how to use the internal test patterns, refer to the section
Setting up an
iScan VP30 Using the Internal Test Patterns and Avia: Guide to Home Theater Calibration
DVD.
To turn the test patterns on and off, use the
Test Pattern On/Off button.
To navigate backwards and forwards through the available test patterns use the < and >
buttons,
respectively.
Auto Standby
The default setting is ‘Off’, which means iScan VP30 is always in Active mode, regardless of the
activity state of the selected input. If Auto Standby is ‘On’, the iScan VP30 goes into Standby mode
30 seconds after the selected input becomes inactive. To see the current setting, press
Up or Down.
Then press the same button again to change the setting.
LED Brightness
This selection allows the user to configure the behavior of the Front Panel LED brightness. The
‘Active’ parameter adjusts the brightness of the Front Panel LED when the menu is being navigated.
The ‘Reduced’ parameter adjusts the brightness of the Front Panel LED during normal usage, when
the menu is not being navigated.
User Mode
You have limited access to the output timing controls in ‘Normal’ mode. In ‘Advanced’ user mode, you
have access to the complete set of output timing controls. push the down button to see the current
setting and the FPD displays either ‘Normal’ or ‘Advanced’ user level. Push the
Down button again to
select the alternate mode.
Serial Port Rate
The serial port is used by the automation system controllers to control the iscan Vp30. The serial port
baud rate defaults to 19200 bps, but can be changed using the
Up or Down button.
The supported baud rates are:
•
1200 bps (1.2K)
•
2400 bps (2.4K)
•
4800 bps (4.8K)
•
9600 bps (9.6K)
•
14400 bps (14.4K)
•
19200 bps (19.2K)
•
38400 bps (38.4K)
•
57600 bps (57.6K)