6
2B. Electrical
Main Power Supply Circuit:
The ATLAS/TITAN/MAGNUM 25-200 are supplied
with 3-5 feet power cord. Connect the power cord to a standard grounded 15
Amp (10 Amp International) power source, according to a local electrical code
only.
2C. Plumbing
When injecting Ozone in to water all measures should be taking to protect the
Generator Cell from water exposure, which may cause internal cell damage. A
small tank with/or an automatic water drain system is recommended.
2D. Gas Connections
The Ozone Generator should be connected by tubing made from material
appropriate for ozone and oxygen applications. Connect the Ozone Generator
according to indications on input and output bulkheads. All efforts should be
made to protect the generator from exposure to excessive pressure fluctuations,
which may lead to the damage of electronic circuitry and Ozone Cell. For
applications where pressure fluctuations are possible we strongly recommend
installation of a buffer tank with an appropriate hi-low pressure switch. It is
VERY IMPORTANT
to protect the Generator from any possible contamination
from the Oxygen Concentrator or from water injection device, by installing
oxygen monitor and filter upstream from the Generator and automatic water
drain device in combination with check valve. Concentration of feed oxygen
should not be below 90%.