background image

4

EN/US/CA/A.mist A.mistT/UM-2239-1

Subject to alteration without prior notice.

SAFETY PRECAUTIONS

4

Type of warning

Warning text

Warning - Hazardous voltage!

The filter unit works with a high electrical voltage. The electrical installation 

must be performed by qualified electricians. Disconnect the power supply to 

the filter unit before it is opened and/or before starting work on the filter unit.

Warning - Do not connect the filter unit to explosive gases! 

Do not connect the filter unit to processing machines that can bring about an 

explosion risk. Furthermore, the filter unit must not be connected to media 

that are highly inflammable without preventative measures being taken to stop 

the spread of the explosion or fire to the filter unit. 

Caution - Read and understand the user’s manual!

Read and understand the user guide before working on the filter unit.

Caution - Qualified personnel only!

All work concerning transport, installation and maintenance must be perfor-

med by qualified personnel.

Risk of trapping injury!

Do not insert your hand into the filter unit when the fan is running. Do not 

wear loosely hanging clothing near the fan when operational. These can be 

sucked into the fan or get caught.

Risk of tipping over!

Always check the weight of the filter unit (technical data, heading 7) before 

lifting. When equipped with an integrated fan unit the centre of gravity of the 

filter unit is relatively high. When transporting the filter unit, secure well - an 

alternative can be to transport the filter unit horizontally.

Heavy products!

Filter cassettes are heavy. Check the current weight of the filter cassette be

-

fore handling. Weight details can be found on the filter cassette’s rating plate 

and under heading 11 “Handling the filter cassettes”.

Lifting equipment or the like must be used during service and inspection 

work above the ground.

Risk of slipping!

Keep the floor clean. Remove oil spill to prevent injury due to slipping.

High noise levels!

If the sound level at the control panel/workplace exceeds 75 dB(A) ear protec

-

tion must be worn.

Dangerous fluids!

Use requisite personal safety equipment with all types of service work, as the 

filter unit can contain liquids dangerous to health. Refer to the product sheet 

for the liquids in question before handling. 

Caution when recirculating air back into the building!

Note that in its standard design the filter unit does not separate gas molecules.

Danger

Skilled 

personnel

Risk of 

personal injury

Summary of Contents for A-mist6C

Page 1: ...EN US CA A mist A mistT UM 2239 1 User s Manual in original Oil Mist Filter A mist6C A mist10 A mist20 A mist60 A mist40T A mist40TF A mist80T A mist80TF EN A mis t US CA A mis T t...

Page 2: ...rting A mist40 80 6 5 5 Floor mounting 6 5 6 Installation 7 6 Operation Design 7 7 Technical Data 8 7 1 Technical data A mist6C A mist10 A mist20 A mist60 8 7 2 Technical data A mist40T TF 9 7 3 Techn...

Page 3: ...er unit Danger Heavy products The filter cassettes are heavy Check the weight of the relevant filter cassette before handling Particulars of their weight is located on the rating plate of the filter c...

Page 4: ...near the fan when operational These can be sucked into the fan or get caught Risk of tipping over Always check the weight of the filter unit technical data heading 7 before lifting When equipped with...

Page 5: ...cessary contact the shipper 5 2 Transporting A mist6C A mist10 A mist20 The filter unit is delivered on a wooden pallet and is wrapped in plastic foil A mist10 and A mist20 have a high centre of gravi...

Page 6: ...hem If they need to be lifted do so according to any of the following methods Fig 1 Use an overhead crane to lift the filter unit stan ding on a wooden pallet Fig 2 Use a fork lift to lift the filter...

Page 7: ...re properly secured when the re tainer arms point upwards If a filter cassette has become loose during the transport secure it and close the service door How to secure see 12 3 3 Connect the drainage...

Page 8: ...h mm inch 350 11 8 620 24 4 620 24 4 620 24 4 620 24 4 620 24 4 620 24 4 Std inlet connection mm inch 125 5 9 160 6 3 160 6 3 200 7 8 200 7 8 200 7 8 400 15 7 Std return oil connection inch R11 4 R11...

Page 9: ...9 Filter cassettes Main filter pc 4 4 Absolute filter HEPA pc 2 2 Performance Max airflow m h cfm 4000 2350 4000 2350 Noise level dB A 1 702 49 7 71 6 25 4 28 8 15 7 12 4 11 8 12 8 48 1 49 8 11 8 25 4...

Page 10: ...cfm 8000 4700 8000 4700 Noise level dB A 1 732 1 The noise level specified in the user s manual is applicable to filter units with external fan 2 The noise level specified has been measured at a dist...

Page 11: ...from the fan to the terminal blocks on the side of the filter unit Warning Dangerous voltage All electrical work must be carried out by qualified electricians Electrical data can be read from the rati...

Page 12: ...US CA A mist A mistT UM 2239 1 Subject to alteration without prior notice 8 3 Electrical connection of A monitor 230V 400V 460V 15 VDC o P max 230V 1A P P ELECTRICAL CONNECTION cont 8 Flow diagram A m...

Page 13: ...otation of the fan motor according to section 2 above If the unit is run with a too high flow there is a large risk that the life span of the filter cas settes will be shortened 4 Pressure drop over t...

Page 14: ...tage 2 Filter stage 1 A mist80T A mist40T CARE MAINTENANCE cont 10 1 In order to get to know your new installation the filter cassettes should be checked once a month during the first six months the f...

Page 15: ...OUR COUNTER DEVICE An hour counter device is also included in our standard equipment It measures and monitors the operation time in hours for the filter unit ALARM On the transformator card there is a...

Page 16: ...e filter cassette HANDLING THE FILTER CASSETTES 12 Warning Use requisite personal protection equipment when performing service work on the filter unit Lifts or the like must be used when carrying out...

Page 17: ...and No 2 centre can be washed several times Wash with water based degreasing agent in a chamber washer Figure C max permissible water tem perature 90 C 194 F After washing the filter must be left to d...

Page 18: ...ue to the normal subatmospheric pressure inside the filter unit It must fit tightly against the filter unit and it must be filled with liquid To be able to use this liquid trap the filter unit has to...

Page 19: ...top of the filter unit place the cover and fasten it with the enclosed bolts Outlet diameter 250mm Sound insolation hood A mist10 A mist20 A mist60 The sound insolation hood is used when there is a n...

Page 20: ...e instructions for use A mist filter units can be supplied with a mounted protective motor contactor The A mist filters unit can be equipped with a frequency converter with integrated pressure sen sor...

Page 21: ...nformation PREFILTER FOR SEVERE DIRT 13 8 STAND ALONE A MONITOR 13 9 A monitor is integrated at the front of nearly all A mist and A smoke filter units as standard With the stand alone A monitor it is...

Page 22: ...e Is it possible to move or pro tect the inlet with a shield to decrease the amount of solid particles sucked into the filter unit A pre filter could also be a solution Poor drainage from the cassette...

Page 23: ...rranty is however only valid if the product is in its original configuration and only when original spare parts have been used when servicing or repai ring the filter unit Some examples on why orignal...

Page 24: ...l documentation Technical writer Staplaregatan 1 SE 531 40 LIDK PING Sverige Tel 46 0 510 48 40 00 We Absolent AB declare under our sole responsibility that the product to which this declaration relat...

Page 25: ...NOTES...

Page 26: ...NOTES...

Page 27: ......

Page 28: ......

Reviews: