A number of accessories are available for the type A•mist
Absolent oil mist filter. Installation instruc-
tions for these are described on the following pages. However, note that the products must be
ordered separately.
ACCESSORIES
13
Return Liquid Hose
The return liquid hose is designed for connection to the
return oil pipe of the filter unit. The outlet of the liquid trap
is not to discharge liquid in such a way that the liquid can
damage adjacent building elements.
Correct installation of the liquid trap is very important due
to the normal subatmospheric pressure inside the filter
unit.
It must fit tightly against the filter unit and the outlet
must be lower than the liquid level.
Liquid trap
The liquid trap is designed for connection to the return oil
pipe of the filter unit.
The outlet of the liquid trap is not to
discharge liquid in such a way that the liquid can damage
adjacent building elements. Correct installation of the liquid
trap is very important due to the normal subatmospheric
pressure inside the filter unit. It must fit tightly against the
filter unit and it must be filled with liquid.
To be able to use this liquid trap, the filter unit has to be
placed
on extension legs (13.2) or a mezzanine.
Receptacle
The liquid trap receptacle is designed for connection to the
return oil pipe of the filter unit. It consists of a tight recep
-
tacle that is transparent enabling the operator to see the
level of liquid in the receptacle.
Correct installation of the liquid trap is very important due
to the normal subatmospheric pressure inside the filter
unit.
It must fit tightly against the filter unit.
To be able to use this liquid trap, the filter unit has to be
placed
on extension legs (13.2).
LIQUID TRAPS
13.1
Steel bucket
The steel bucket liquid trap is designed for connection
to the return oil pipe of the filter unit. It consists of a tight
bucket with a fitted level indicator enabling the operator to
see the level of liquid in the bucket.
Correct installation of the liquid trap is very important due
to the normal subatmospheric pressure inside the filter
unit.
It must fit tightly against the filter unit.
To be able to use this liquid trap, the filter unit has to be
placed
on extension legs (13.2).