background image

Absco Industries

Assembly Instruction Manual

SKILLION SHED

N3/C1 FRAME KIT

FOR SPACE SAVER AND

Model: CYCSKRSK

02/03/21

1.1

1  

 

 

REVERSE SKILLION MODELS

DOWNLOAD

 

OUR APP FOR

ASSEMBLY

VIDEOS

LEAVE A REVIEW

Tell us about your experience and 

receive a $20 Coles Gift Card.

Visit

 

www.abscosheds.com.au/review

AU: 1800 029 701

NZ: 0800 466 444

[email protected]

www.abscosheds.com.au

This kit is applicable to the following sheds:

The addition of this frame kit will increase the 
wind rating of the specified sheds to

Wind rating: N3/C1 as per AS4055-2012.
Suitable for specific cyclonic regions

30152SK
30151SK
23151SK
23151RSK

WARNING: This shed must be anchored to a 
100mm thick concrete slab with the concrete 
anchors supplied.
Failure to do so will result in the shed not 
having the structural integrity required to 
endure a severe storms or cyclonic event.

WARNING: Doors must remain closed with 
all padbolts properly secured during severe 
storms or cyclonic event.

Where information conflicts with the original 
non-cyclonic instruction manual, this 
document is to be referenced.

View of frame kit applied to

30152SK

Summary of Contents for CYCSKRSK

Page 1: ...will increase the wind rating of the specified sheds to Wind rating N3 C1 as per AS4055 2012 Suitable for specific cyclonic regions 30152SK 30151SK 23151SK 23151RSK WARNING This shed must be anchored to a 100mm thick concrete slab with the concrete anchors supplied Failure to do so will result in the shed not having the structural integrity required to endure a severe storms or cyclonic event WARN...

Page 2: ... The bracing material supplied is 80 x 40 mm galvanised steel channel similar to that used in steel house framing Some channels are required to be cut to specific lengths using a hacksaw SITE PREPARATION The site for the shed must be level An uneven surface may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately If using a ...

Page 3: ...otch on one end only K 20mm Tab notch on both ends L 45mm Lip notch on one end only M 45mm Lip notch on both ends N 20mm Tab notch 45mm Lip notch P 20mm Tab notch 45mm Lip notch on both ends R One end 20mm Tab notch 45mm Lip notch S SPECIAL NOTCHING not noted above FRAME SECTION IDENTIFICATION GUIDE The first letter of the part number is used to identify the notching type EG K2940 see below for re...

Page 4: ...220 PACK FAST001 2 HINGE 6 HOLE FAST012A 8 3 16 x 1 2 PAN HD BOLT FAST002 1 3mm POP RIVET PACK 50 PACK FAST009 8 3 16 NYLOC NUT FAST003 6 MULTIPURPOSE BRACKET MPB BKT17 1 10G x 5 8 WAFER TEK SCREW 300 PACK FAST014 1 DOUBLE DOOR ANCHOR BRACKET BKT12 4 PADBOLT FAST006 4 CORNER BRACKET BKT10 2 PADBOLT HASP FAST007 2 M10 DYNABOLT M10 NUT BOLT BRACKET 8 PACK ANCHOR KIT 4 DOOR PLATE 2 CO 2 ZINC CO12A 1 ...

Page 5: ...d to be installed to reduce these distances The fastener intended at these positions is FAST001 a 10mm self tapping screw Pre drill and reinforce with extra screws at 148mm centres in the following locations B Roof panel to wall G Wall sheet to wall channel inside Pre drill and reinforce with extra screws at 296mm centres in the following locations A All sheet to sheet connections D Wall corners E...

Page 6: ...NTERIOR VIEW G Wall sheet to top wall channel Pre drill from inside the shed through the inside face of the top channel and into the wall sheet at 148mm centres every pan and then fix with a screw Do this on the front and back walls only means pre drill 3mm hole and fix with FAST001 D Additional FAST001 for rear wall Additional FAST001 for front wall of a double door model ...

Page 7: ...des of the boxed sections Align tek screws 296mm apart This is approximately 2 sheet corrugations in distance If spaced correctly the screw heads will line up with corrugations of the sheets and will make for a flush finish against the wall or roof 2 Slide the 38mm side into the 40mm side as shown 4 Apply firm pressure to each side of the boxed section to firmly lock it into position NOTE Only the...

Page 8: ...n electric or battery drill for installation Do not attempt to fasten tek screws by hand If available make sure that the drill has the slow speed and high torque settings selected Fit the supplied driver bit into the chuck of the drill Place the tek screw onto the tip of the driver and place the tek screw into position using the weight of the drill to prevent it from moving Once in position apply ...

Page 9: ... 30152SK 30151SK 23151SK 23151RSK Not to scale Double door model shown for illustrative purposes C2950 BKT17 C0660 K0285 BKT17 C1555 C2940 S1785 BKT10 C1220 BKT12 NOTE For 2 3m wide structures the following parts will need to be cut to length C2950 to 2210mm C2940 to 2000mm If shed is on a rebated slab S1785 will need to be cut to suit rebate height Horizontal wall framing is boxed ...

Page 10: ...od at 890mm This will act as a height template to mark the drilling positions when outside the shed to fix the internal bracing At the front of the shed place a horizontal boxed section at 870mm height and tek screw in position as shown on the right Make sure that the boxed section is pushed firmly against the side wall This will allow the door stud to be installed later Now secure to the rear wal...

Page 11: ...ll Connect them into a boxed configuration do not tek screw yet Place the unfastened boxed pieces against the rear wall and slide them apart until they make contact with both side walls It should look similar to what is shown on the right box them at this length Now secure to the rear wall with tek screws from outside the shed at 148mm spacings Side wall 80mm Back wall Corner detail of back wall b...

Page 12: ...ontact with it and the brace on the other wall This is shown below Now the framing is at the correct length proceed to fix them together and then use tek screws to fix it to the side wall from the outside of the shed at 148mm spacings Side wall Side wall Back wall Previously installed wall bracing on the left and new side wall bracing on the right 5 Use corner brackets BKT10 to secure the rear sid...

Page 13: ...bracing with two tek screws as shown NOTE Instances where the door stud is just short of touching the roof At the top box in C0400 to span the gap 3 Fix the stud to the wall sheet from outside the shed with tek screws at a 296mm spacing 4 Fix a multipurpose bracket BKT17 at the top and bottom of each door stud using tek screws as shown S1785 S1785 has a rebate so it fits over the wall brace BKT17 ...

Page 14: ... the centreline of the bracing Two multipurpose brackets BKT17 are used per roof brace 3 Proceed to drill a hole in every 2nd flat section of the roof sheet 4 While one person holds the roof brace in position use hex head teks screws with neoprene washers to fix the framing from the outside of the shed IMPORTANT Do not sit stand or walk on the roof or apply unnecessary pressure of the sheeting dur...

Page 15: ...d level surface and use one tek screw at each join NOTE If the door has been completely assembled as per original instruction manual you will need to remove the diagonal door braces 3 Make sure the frame is square and fix with a second tek screw at each join 4 Turn frame over and repeat last step 1 Seal any brace holes using the supplied pop rivets FAST007 Perform from the outside of the door K064...

Page 16: ...ST006 4x nut FAST005 4x bolt FAST004 NOTE Fit to exterior for double doors Horizontal position D 1x Padbolt FAST006 1x Door plate 12A 1x Hasp FAST007 6x Self tapping screws FAST001 10 Drill 10mm holes in the jamb above the door ref image B and the channel below the door ref image C These align with the vertical padbolt shafts of double doors DOOR BRACING 6 Use tek screws to fix the frame to the do...

Page 17: ...bolt requires drilling into the concrete slab using a masonry bit Holes must have a minimum slab edge distance of 60mm Bolt and nut through the wall sheet requires the drilling of a 10mm hole through the wall sheet Inside view of typical anchor Outside view of typical anchor Door stud have a single anchor through a BKT17 Fixed by four tek screws Double door openings are required to be anchored usi...

Page 18: ... FOR SPACE SAVER AND Model CYCSKRSK 02 03 21 1 1 18 REVERSE SKILLION MODELS ANCHORING LAYOUT Slab dimensions below illustrate the minimum required anchors per wall Ensure that anchors are evenly spaced along wall 2360mm for 2 3m wall 3100mm for 3 0m wall 1620mm for 1 5m wall ...

Page 19: ...ers wheelbarrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other product...

Page 20: ...s of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin absco com au You will be required to produce proof of purchase this is at discretion of the manufacturer at the time of the claim The manufacturer bears the cost of replacing the products or spare p...

Page 21: ... equipment and should not be used for articles that may be prone to damage if they come into contact with moisture 3 Major Defects If the manufacturer is satisfied that the defect is a major defect the purchase price may be refunded in lieu of providing a replacement product or repairing the product This warranty is provided in addition to other rights and remedies you have under law Our goods come...

Reviews: