background image

Absco Industries

Assembly Instruction Manual

Model: CYC15

02/03/2021

1.0

6  

 

 

N3/C1 FRAME KIT

FOR 1.5m WIDE TO
1.5m DEEP MODELS

INSTALL EXTRA FASTENERS - INTERIOR VIEW

means pre-drill 3mm hole 

and fix with FAST001

D

G”

 - Wall sheet to top wall channel.

Pre-drill from inside the shed through the inside face of the top channel and into the wall sheet 
at 

148mm

 centres, (every pan) and then fix with a screw. Do this on the front and back walls only.

Additional FAST001 for rear wall

Additional FAST001 for front wall.

C”

 - Roof panel to ridge beam.

Pre-drill from inside the shed upward through the ridge beam and into the roof panel at 

148mm

 

centres, (every pan) then fix with a screw. Some screws will already be in these positions, skip these.

For illustrative purposes fasteners are shown on just one side of the 

ridge beam.

Repeat again to other side.

Summary of Contents for CYC15

Page 1: ...ease the wind rating of the specified sheds to Wind rating N3 C1 as per AS4055 2012 Suitable for specific cyclonic regions 15151GK 15151SK 15141RK WARNING This shed must be anchored to a 100mm thick c...

Page 2: ...aterial supplied is 80 x 40 mm galvanised steel channel similar to that used in steel house framing Some channels are required to be cut to specific lengths using a hacksaw SITE PREPARATION The site f...

Page 3: ...otch on one end only K 20mm Tab notch on both ends L 45mm Lip notch on one end only M 45mm Lip notch on both ends N 20mm Tab notch 45mm Lip notch P 20mm Tab notch 45mm Lip notch on both ends R One end...

Page 4: ...TAPPING SCREW 220 PACK FAST001 1 HINGE 6 HOLE FAST012A 8 3 16 x 1 2 PAN HD BOLT FAST002 1 3mm POP RIVET PACK 50 PACK FAST009 8 3 16 NYLOC NUT FAST003 8 MULTIPURPOSE BRACKET MPB BKT17 1 10G x 5 8 WAFE...

Page 5: ...e fastener intended at these positions is FAST001 a 10mm self tapping screw Pre drill and reinforce with extra screws at 148mm centres in the following locations B Roof panel to wall C Roof panel to r...

Page 6: ...el and into the wall sheet at 148mm centres every pan and then fix with a screw Do this on the front and back walls only Additional FAST001 for rear wall Additional FAST001 for front wall C Roof panel...

Page 7: ...xed sections Align tek screws 296mm apart This is approximately 2 sheet corrugations in distance If spaced correctly the screw heads will line up with corrugations of the sheets and will make for a fl...

Page 8: ...battery drill for installation Do not attempt to fasten tek screws by hand If available make sure that the drill has the slow speed and high torque settings selected Fit the supplied driver bit into t...

Page 9: ...141RK Not to scale GENERAL NOTE If shed is on a rebated slab S1785 will need to be cut to suit rebate height 15141RK Roof brace orientation will be perpendicular to what is shown Roof braces will be t...

Page 10: ...e and use one tek screw at each join NOTE If the door has been completely assembled as per original instruction manual you will need to remove the diagonal door braces 3 Make sure the frame is square...

Page 11: ...C 1x Padbolt FAST006 4x nut FAST005 4x bolt FAST004 Horizontal position D 1x Padbolt FAST006 1x Door plate 12A 1x Hasp FAST007 6x Self tapping screws FAST001 9 Drill 10mm holes in the jamb above the...

Page 12: ...This will act as a height template to mark the drilling positions when outside the shed to fix the internal bracing At the front of the shed place a horizontal boxed section at 870mm height and tek s...

Page 13: ...crews from outside the shed at 148mm spacings Side wall 80mm Back wall Corner detail of back wall brace C2950 BRACING FOR SIDE WALLS Construction for the side wall opposite to the door is similar to t...

Page 14: ...the back wall This is shown below For 15141RK this C1220 should be trimmed to 1190mm to help the door stud fit the wall brace C1220 C0660 One end of the wall brace dimensioned from the outside of the...

Page 15: ...ud to the wall bracing with two tek screws as shown NOTE Instances where the door stud is just short of touching the roof At the top box in C0400 to span the gap 3 Fix the stud to the wall sheet from...

Page 16: ...e of the bracing 3 Proceed to drill a hole in every 2nd flat section of the roof sheet 4 While one person holds the roof brace in position use hex head teks screws with neoprene washers to fix the fra...

Page 17: ...b ANCHORING METHODS Fixing M10 dynabolt requires drilling into the concrete slab using a masonry bit Holes must have a minimum slab edge distance of 60mm Bolt and nut through the wall sheet requires t...

Page 18: ...ows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked ab...

Page 19: ...of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin...

Page 20: ...equipment and should not be used for articles that may be prone to damage if they come into contact with moisture 3 Major Defects If the manufacturer is satis ed that the defect is a major defect the...

Reviews: