Part number 20220, Rev 0 
 

 

STARTING  

There are no compressor shipping bolts to loosen or valves to open.  All that is necessary after 
the  unit  has  been  properly  leveled  is  to  plug  the  service  cord  into  an  electrical  outlet    When 
starting this new appliance, allow the cabinet to operate a minimum of four hours or until it has 
started  cycling  normally  before  placing  product  in  the  cabinet.    The  motor  compressor  may 
start and stop several times when the unit is first started or after defrosting, especially if the 
weather is very hot.  This is normal.  The motor compressor will cycle normally as soon as the 
excess heat has been removed.    

 

Shelf Installation  

 

Hook  shelf  clips  onto  pilaster  strips  (see  Illustration).  Position  all  four  shelf  clips  equal  in 
distance from the floor for flat shelves. Wire shelves are oriented so that cross support bars are 
facing down. 

 

Place shelves on shelf clips making sure all corners are seated properly. 

 

 

 

 

 

Summary of Contents for PH-ABT-UCFS-0204G

Page 1: ...driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being...

Page 2: ...EPARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left OR ri...

Page 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Page 4: ...on this unit POWER SOURCE The supply circuit to this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements...

Page 5: ...product in the cabinet The motor compressor may start and stop several times when the unit is first started or after defrosting especially if the weather is very hot This is normal The motor compresso...

Page 6: ...perly The digital temperature controller is located on the front panel of the refrigerator It normally displays the current temperature inside of the unit and has several additional functions includin...

Page 7: ...ng 25 minutes will take the unit out of the defrost cycle PROGRAM MODE Note Most of the functions in Program Mode are for factory use only and should not be adjusted This procedure will show you how t...

Page 8: ...ides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inch...

Page 9: ...the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost...

Page 10: ...bove 40C 104F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount o...

Page 11: ...ter out of sponge or cloth before cleaning around controls light bulb or any electrical parts Glass Doors if applicable Soap and water Clean the glass with a mild detergent and water on a soft cloth o...

Page 12: ...e paid by the customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compr...

Page 13: ...t damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with t...

Reviews: