background image

Part number 20080, Rev 0 

 

INSTALLATION  

UNCRATING 

Move your refrigerator as close to the final location as possible before unpacking. Remove the 

wooden planks or skid.  The location should be as close as possible to the power outlet so the 

extension cord is not needed. This unit requires a 

minimum of 4 inches of air flow space in 

back and 3 inches on the sides.

  Do not store material on the top of this unit and leave at least 

12 inches of clearance on top.  

 

PLEASE NOTE!

  Your refrigerator or freezer is designed for 

INDOOR USE and should be operated in an air conditioned space 

with temperature between 65°F to 85°F. 

 

 

POWER SOURCE 

The supply circuit to this cabinet must 

conform to all National and Local 

Electrical Codes.  Consult the cabinet 

Serial-Data plate for voltage, cycle, 

phase, and amp requirements before 

making connection.   VOLTAGE SHOULD 

NOT VARY MORE THAN 5% FROM SERIAL 

PLATE RATINGS.  A separate circuit is 

recommended to prevent possible loss of product due to over-loading or failure of other 

equipment on the same circuit.  PROTECT THE CIRCUIT WITH A 20 AMP DELAY-TYPE FUSE OR 

CIRCUIT BREAKER.  Do not use an extension cord.  Be sure your 

unit is properly grounded.  Use the 3-prong plug provided into a 

3-prong grounded outlet. (Only this method complies with 

national electrical codes, local codes and ordinances.)  Unless the 

above grounding method is followed, you are not protected 

against severe or lethal shock in the event of a short circuit of an 

electrical component or wiring of the unit. 

 

 

 

Summary of Contents for ABT-23SS-GP

Page 1: ...delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When con...

Page 2: ...ARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper w...

Page 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Page 4: ...o this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VA...

Page 5: ...INSTALLATION Hook shelf clips onto pilaster strips see Illustration Position all four shelf clips equal in distance from the floor for flat shelves Wire shelves are oriented so that cross support bar...

Page 6: ...n cooling of the product When loading the top shelf avoid blocking the evaporator fan s There should be at least 4 inches of clearance below the fan s to allow proper air flow Do not overload the unit...

Page 7: ...of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a setpoint is attained until an alarm condition is declared This prevents spurio...

Page 8: ...wn arrow The display will show Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control setpoints NOTE The temperature control setpoi...

Page 9: ...to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOWN key to choose the desired setting Press SET again to lock it in Press SET and UP to return to Operating Mode...

Page 10: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Page 11: ...prevent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURIN...

Page 12: ...ill not harm the steel s passive layer Stainless steel pads can also be used but the scrubbing motion must be in the directing of the polishing lines Clean with the polish lines Some stainless steels...

Page 13: ...ywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode in the natural environment Contrary to popular belief Stain...

Page 14: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Page 15: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Reviews: