Programming Mode 

Note: The TempTech-2000 programming mode gives access to several 

functions that are not intended for user adjustment. The procedures 

below provide direction to the functions that you can adjust. Please do 

not attempt to change any of the other functions in the programming 

area or your unit may be damaged or become unstable.    

 

Locking and Unlocking the Control 

The control keys can be locked out to prevent inadvertent operation.  

-

 

To lock the control keys, simultaneously press and hold the up arrow and the down 

arrow. The display will show “POF”.  At this point you can only use keys to view the SET 

temp and the minimum and maximum stored temperatures.  

-

 

To unlock the control keys, simultaneously press and hold the up arrow and the down 

arrow. The display will show “Pon”. The control keys are now unlocked and you can 

perform the programming functions below.  

 

Adjusting the temperature control setpoints: 

NOTE: The temperature control setpoints are preset at the factory to 

provide the desired air and product temperatures inside of the unit and 

require no further adjustment. Please contact the manufacturer’s 

Technical Service Department before making any adjustments to 

determine if adjustment is necessary and, if so, to make sure it is 

performed properly. 

 

 

 

-

 

To set the compressor off setpoint, press and hold the SET key for 2 seconds. The C or F icon 
will flash. Use the up or down keys to change the value. Press SET again to lock in the value.

 

-

 

To set the compressor on setpoint, you will need to adjust the hysteresis  (differential) 
setting. This is the number of degrees the controller will allow temperature to drift up until 
it restarts the compressor. For example, if the SET point is 3 degrees Celsius and the 

Summary of Contents for ABT-23SS-GP

Page 1: ...delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When con...

Page 2: ...ARTMENT please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper w...

Page 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Page 4: ...o this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VA...

Page 5: ...INSTALLATION Hook shelf clips onto pilaster strips see Illustration Position all four shelf clips equal in distance from the floor for flat shelves Wire shelves are oriented so that cross support bar...

Page 6: ...n cooling of the product When loading the top shelf avoid blocking the evaporator fan s There should be at least 4 inches of clearance below the fan s to allow proper air flow Do not overload the unit...

Page 7: ...of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a setpoint is attained until an alarm condition is declared This prevents spurio...

Page 8: ...wn arrow The display will show Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control setpoints NOTE The temperature control setpoi...

Page 9: ...to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOWN key to choose the desired setting Press SET again to lock it in Press SET and UP to return to Operating Mode...

Page 10: ...placements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerat...

Page 11: ...prevent leakage Door will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURIN...

Page 12: ...ill not harm the steel s passive layer Stainless steel pads can also be used but the scrubbing motion must be in the directing of the polishing lines Clean with the polish lines Some stainless steels...

Page 13: ...ywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode in the natural environment Contrary to popular belief Stain...

Page 14: ...Y In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship...

Page 15: ...od or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage cause...

Reviews: