11
11/14 - Installation instructions for an automatic safety cover
2.4.12 Fig 36: Levelling course wall hook option.
For levelling course fixing, the water level must be
between -5 cm and -10 cm.
Fig. 36
2.4.13 Fig. 37
Fix the wall hook to the support using the washers
and the M5 nuts.
Cover the nuts using the covers.
Fig. 37
2.4.14 Fig. 38
Fix the levelling course to the support using the
TFHC M5 x 16 screws.
Fig. 38
2.4.9 Fig. 33
Close the pool to check the harpooning on each
lock.
If necessary, horizontally adjust the wall hooks using
the oblong holes.
Cover the screw heads using the covers.
± 5 mm
Fig. 33
2.4.10 Fig. 34
Locking indicator
On every harpoon, check that the locking indicator
is out to check that the system has been engaged.
Fig. 34
Lock not engaged.
2.4.11 Fig. 35
Fig. 35
Lock engaged.