This document is the property of AS POOL - NextPool group and cannot be reproduced or communicated without our authorisation.
10
Installation instructions for an automatic safety cover - 10/14
2.4.7 Fig. 31
Open the pool cover a few centimetres, then drill
the pool wall to diameter 6 to a depth of 50 mm.
Caution: for the wall hook drilling part, it is better
to lower the water level slightly and then raise it
back again.
Fig. 31
2.4.8 Fig. 32
Position the TRHC M5 x 30 screws, washers and
anchors on the wall hooks.
Screw the screws into the anchors until they widen
slightly.
Make sure they are level and horizontal.
Fig. 32
2.4.5 Fig. 29
In the closed position, check that the wing brush is
not too far from the wall or too compressed ± 5 mm
on either side compared to the pool wall.
± 5 mm
Fig. 29
If the gap is too wide, the slats could drift to one side
and the lock may not harpoon the wall hook.
If the brush is too compressed, the thrust and
harpooning force will be diminished. In that case,
cut the brush hairs using scissors in order to remove
the gap and have the hairs barely touching the wall.
2.4.6 Fig. 30
When the cover is closed and in contact with the
wall, place the wall hooks on the locks.
Make sure to position the wall hooks properly
opposite each lock to obtain perfect alignment and
proper operation.
Mark the hole locations on the wall using a pencil.
Fig. 30