PROBOIL.2X user & installation guide v1e-2
12
11.
It is normal for new filters to lose a small amount
of loose carbon when first used and will dissipate
with flushing, whilst harmless to consume if the
carbon particles are not flushed prior to
connection to the boiler they may partly block the
boiler and reduce the flow rate. You must flush the
filter for at least 2 litres with cold water or until
the water become clear (without black carbon
particles).
12.
Flushing the filter
(Only If your tap DOES include a
cold filtered water dispense option):
a.
Place the outlet of the filter cartridge over the
bowl.
b.
Turn the Tee valve partly and slowly to the
“on/open” position (fig. 1).
c.
Once the Tee valve is “open” air within the
filter will purge (spitting is normal at first) and
the water will start to flow from the filter exit.
d.
Run the water into the bowl until it runs clear
of loose carbon.
e.
Turn the Tee valve fully to the “off/closed”
position (fig. 2).
13.
Flushing the filter
(Only If your tap DOES NOT
include a cold filtered water dispense option):
a.
Place the outlet of the filter cartridge over the
bowl.
b.
Turn the 98° tap handle to the “on/open”
position.
c.
Once the handle is “on/open” air within the
filter will purge (spitting is normal at first) and
the water will start to flow from the filter exit.
d.
Run the water into the bowl until it runs clear
of loose carbon.
e.
Turn the 98° tap handle fully to the “off/closed”
(vertical) position.
(fig1.)
(fig2.)
14.
Push the “outlet” flexible blue pipe firmly and fully
into the new filter cartridge outlet.