Storage
Operation and interim storage in aggressive, damp environments or outdoors may
lead to corrosion and other damage. Maintain the storage temperature in the range of
–20 °C to +40 °C.
Training of Personnel
Only trained and instructed personnel who have read and understood all points in the
operating instructions may work on the product. The personnel must also be able to
control the operating states, and identify and implement the interrelated safety
aspects. Personnel in training may only work on the product under the supervision of
qualified personnel.
Fault Localisation, Troubleshooting
Fault
Possible cause
Remedy
Pump is running, but not
delivering grease
Air in the grease or
intake system
Press the assembled
follower plate against the
grease. Open the bleed
screw and run the system
until a constant flow of
grease comes out. Close
the bleed screw again.
Pump doesn't apply any or
too low of a pressure
Leakage
Inspect the hoses and
fittings
Air pressure too low
Check the compressed air
supply
The signal for the empty
message is not generated.
Positioning of the
sensor is incorrect.
Control of the position
CAUTION
All of the faults described below may only be resolved by trained, qualified
personnel.