60
10. TECHNICAL
SPECIFICATIONS
Model code 11kW
1W1121
1W11K2
1W11N2
1W1101
1W11K1
1W11N1
Rated voltage
230/400 V
230/400 V
Grid frequency
50 Hz
50 Hz
Current
16 A
16 A
Charging output
11 kW
11 kW
Charging connection
Type 2 charging socket
Type 2 charging cable (ca. 6m)
Phase system
3-phase
3-phase
Residual-Current Devices
RCCB, Type A, 30 mA
RCCB, Type A, 30 mA
DC fault current detection
DC-RCM, I
n d.c.
≥
6 mA
DC-RCM, I
n d.c.
≥
6 mA
EVCC
2
2
Compliance
IEC 61851-1
IEC 61851-1
Control / Customization
Internal RS485 interface
Internal RS485 interface
Terminal block
up to 50 mm²
up to 50 mm²
Operating temperature
-30°C to 50°C
-30°C to 50°C
Storage temperature
-30°C to 85°C
-30°C to 85°C
Rel. humidity
5 to 95% (no condensation)
5 to 95% (no condensation)
Class of protection
I
I
Degree of protection (housing)
IP44
IP54
Overvoltage category
III
III
Dimensions
272 x 221 x 116 mm (H x W x D)
272 x 221 x 116 mm (H x W x D)
Weight per unit
ca. 3 kg
ca. 4.5 kg
Summary of Contents for eMH1 WALLBOX
Page 1: ...eMH1 Wallbox Operating Manual EN ...
Page 4: ...4 1 Safety and user information 5 SAFETY FIRST ...
Page 13: ...13 2 Your model variant 14 3 Components included 18 4 Accessories 19 INTRODUCTION ...
Page 23: ...23 CHARGING PROCEDURE 13 Charging 24 ...
Page 38: ...38 6 Error messages 39 7 Display window 50 8 Shutdown 54 RESOLVING ERRORS ...
Page 64: ...64 10 TECHNICAL SPECIFICATIONS 221 mm 116 mm 272 mm ...