LED presets
Only green LEDs
Only blue LEDs
Both LEDs
6. ERROR MESSAGES
Sequence F3
The automatic self-test of the internal RCM14 has returned an error, or a DC fault current
has been detected in connection with the vehicle
The green and blue LEDs alternately flash twice each
200ms
200ms
200ms
200ms
200ms
200ms
200ms
200ms
200ms
200ms
1
If the error is occurring for the first time, the
charging procedure is interrupted for 30 seconds
and then restarted automatically. The charging
procedure is cancelled. A new charging procedure
is only possible after disconnecting the vehicle from
the Wallbox.
2
Take the Wallbox out of operation permanently.
Shutdown: p. 54
Check the vehicle for electrical faults in the
charging system. Contact a qualified specialist
repairer for this purpose.
•
When error messages are displayed
continuously,
•
take the Wallbox out of operation
permanently.
Shutdown: p. 54
•
Contact the specialist electrical
contractor
•
Should the problem persist,
please contact ABL technical support.
Technical support: p. 70