ABL eMH1 WALLBOX Installation And Operating Manual Download Page 8

intrOductiOn

4

Introduction

Congratulations on the purchase of your eMH1 Wallbox by ABL! 

  

With this wallbox from our “Electric Mobility Home“ series, you have chosen an inno-

vative as well as future-proof product that guarantees particularly high operating safety 

while featuring extremely compact dimensions.
eMobility helps to save natural resources and protect the environment sustainably. 

ABL is, with its eMH1 family of products, a leading supplier in this area. The eMH1 

combines progressive and pleasing design with intuitive functionality: According to 

their requirements, users may select from models with a variety of features developed 

for domestic and semi-public applications.
The eMH1 series wallboxes are constantly developed further and at all times comply 

with the regulations and norms for the charging of electric vehicles applicable through-

out Europe according to IEC 61851-1, Mode 3.
If you are looking for additional information about your wallbox or would like to find out 

more about available accessories and the remaining ABL product range, please visit 

our website at 

www.abl.de

Product description

Your eMH1 Wallbox allows you to comfortably and safely charge electric vehicles ac-

cording to IEC 61851-1, Mode 3. Switching layout, cable diameters and charging con-

nectors of the eMH1 are designed for the shortest possible charging times.
We place the highest value on user safety in all our products. Almost all eMH1 Wallbox 

models therefore feature an internal residual current circuit breaker and/or an integrat-

ed DC fault current detector (depending on the model variant). In combination with the 

protection devices of your electrical infrastructure and the fault current protection of 

your electric vehicle, these measures ensure effective protection against short circuit, 

electric shock and other operational hazards.
The eMH1 Wallbox is especially easy to operate in day-to-day use: Two LED lights in 

the upper part of the housing allow you to check the current operating status at any 

time. Should a malfunction occur, you can identify the cause by its specific LED error 

code without having to open the housing. Access to the internal switching devices is 

controlled through the lockable cover shield – this way you can ensure that the housing 

can only be opened by authorized users.
A common characteristic of all eMH1 models is the particularly space-saving hous-

ing made from durable plastic, which effectively protects the internal electric circuits 

against environmental influences and unauthorized access. In general, all model vari-

ants of the EVSE 803 and 813 series should be installed and taken into operation by a 

qualified electrical contractor. Your local distributor will be happy to arrange specialist 

installation for you at your desired location.

Summary of Contents for eMH1 WALLBOX

Page 1: ...Wallbox eMH1 VERSION EMH1 803 813 2017 10 20 ARTICLE NO 0301411_b Installation and operating manual EVSE 803 813...

Page 2: ...Bayerische Elektrozubeh r GmbH Co KG Albert B ttner Stra e 11 91207 Lauf Pegnitz Germany Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 Web www abl de Mail info abl de Customer Support Phone 49 0 9123 18...

Page 3: ...Package contents and unpacking 5 Available accessories 6 Installation and power supply connection 7 Prerequisites for the mounting site and installation 7 Preparation and mechanical installation 8 El...

Page 4: ...Checking the internal RCCB 17 Taking the device out of operation 18 Appendix 20 Technical specifications 20 Standards guidelines 20 Trademarks 21 CE certification and compliance declaration 22 Glossar...

Page 5: ...ion itself or to other electric devices Ac tions marked with this symbol must be carried out with special care PLEASE NOTE Sections marked with this symbol draw attention to further important in forma...

Page 6: ...s been otherwise damaged Please pay particular attention to the following points Read this manual carefully Keep this manual in a safe place where all users can always access it Heed all warnings Foll...

Page 7: ...x is intended for connection to and operation on 230 or 230 400 V 50 Hz mains power only Power supply cables may be installed below or above the wall surface The cable should enter the device via the...

Page 8: ...f the eMH1 are designed for the shortest possible charging times We place the highest value on user safety in all our products Almost all eMH1 Wallbox models therefore feature an internal residual cur...

Page 9: ...urrent detector three phase charging output 11 kW EVSE 813 230 V 50 Hz 32 A Identical to the EVSE 803 model variant but with a charging output of 7 2 kW CAUTION The information and technical specifica...

Page 10: ...lbox For the models of the EVSE 803 and 813 series the following components are available DESIGNATION MODEL NUMBER QUANTITY Mounting pole For mounting all eMH1 Wallbox mod els with or without bracket...

Page 11: ...r The wallbox must be installed where it is freely accessible to all authorized users Ideally the mounting site should already provide connection to the power supply If not a separate supply must be i...

Page 12: ...vehicle comfortably with the charging connector of the eMH1 The cable must not under any circumstances be strained when connected to the vehicle Preparation and mechanical installation After determin...

Page 13: ...illing template 1 Place the included drilling template vertically on the chosen mounting surface Use a spirit level if required CAUTION Check the measurements on the drilling template with a calibrate...

Page 14: ...e wall bracket in position using the included 5 x 60 torx headed screws 8 Seal the openings on the wall bracket with the included sealing grommets Electrical installation of your the wallbox The elect...

Page 15: ...L3 Neutral Blue N Protective earth Green Yellow PE DANGER The above color coding is not internationally standardized Should the in dividual wires in the power supply cable be color coded differently p...

Page 16: ...aker RCCB during vehicle charging This circuit breaker is especially required in cases where your electric vehicle does not provide any DC fault current protection itself You can find information abou...

Page 17: ...up into a compact shape and store it in a way that prevents it from being damaged by external mechanical forces Although the cable and connector are de signed to withstand high mechanical stresses yo...

Page 18: ...blue LED will be illuminated continuously while the con nection between wallbox and vehicle is being established When the charging procedure begins the blue LED will be extinguished and the green LED...

Page 19: ...e illuminated continuous ON flash be extinguished continuous OFF During normal operation the following operating states are shown Left LED Right LED DESCRIPTION OFF flashes every 5 seconds The wallbox...

Page 20: ...e vehicle If the error recurs the indicator LEDs continue to show the error code No charging occurs in this operating state CAUTION If the wallbox continues to show error messages during operation wit...

Page 21: ...quence The wallbox detects a malfunc tion All errors shown by the indicator LEDs relate to vehicle based functions see page 16 The wallbox re initiates the charging procedure ev ery 30 seconds Should...

Page 22: ...k the pivot lever of the internal RCCB if present into the 0 position connection to the power supply is interrupted 3 Lock the cover shield again Now the EVSE 803 813 cannot be used for charging To de...

Page 23: ...bage collection but must be taken to a collection point for electrical electronic waste Please observe all current national and regional legal regulations You can get further information from your mun...

Page 24: ...meter Control Customization internal RS485 interface Terminal block up to 6 mm2 up to 6 mm2 Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensati...

Page 25: ...ctive charging systems for electric vehicles Part 22 AC charging station for electric vehicles HD 60364 7 722 2012 Low voltage installations Part 7 722 Power supply for electric vehicles Classes of pr...

Page 26: ...eviations from the wider eMobility area ABBREVIATION DESCRIPTION MEANING BEV Battery Electric Vehicle Electric vehicle 100 electric use DC RCM Direct Current Residual Current Monitor Monitoring device...

Page 27: ...structions must always be left to a qualified electrical contractor who will connect the device to the local power supply You may however carry out the mechanical installation of the wallbox and drill...

Page 28: ...provisions ABL provides the legally prescribed guarantee period as well as a warranty of the same duration for the country in which the product was purchased Should the product be operated in another...

Page 29: ...persons or force majeure Any assumed guarantees including a guarantee of marketability or suitability for spe cific uses are restricted to the warranty period Disposal advice The crossed out trash ca...

Page 30: ...Albert B ttner Stra e 11 D 91207 Lauf Pegnitz Tel 49 0 9123 188 0 Fax 49 0 9123 188 188 info abl de www abl de ABL SURSUM Bayerische Elektrozubeh r GmbH Co KG MADE IN GERMANY...

Reviews: