reSOlving errOrS
15
Resolving errors
Your eMH1 Wallbox is engineered for maximum operational safety and the highest
possible charging reliability. The RCCB and DC fault current detector recognize all inter-
nal malfunctions and switch the device off immediately.
Should a malfunction occur in practice, this is shown by the
indicator LEDs on the upper part of the housing as an error
code. The following chapter describes how you recognize op-
erating states as well as error codes and which measures you
must take to resolve them.
Operating states
The two indicator LEDs on the left above the front cover shield show the current oper-
ating status of the eMH1 Wallbox. To indicate certain operating states, the LEDs may
...
• ... be illuminated (continuous ON)
• ... flash
• ... be extinguished (continuous OFF).
During normal operation, the following operating states are shown:
Left LED
Right LED
DESCRIPTION
OFF
flashes
every 5
seconds
The wallbox is ready for operation, the vehicle may be con-
nected for charging at any time.
OFF
illuminated The vehicle is connected and has been detected. Next, the
charging procedure will start automatically.
flashes
illuminated The vehicle is currently being charged
illuminated illuminated Charging is complete, the wallbox can be unplugged from
the vehicle.
PLEASE NOTE!
In principle, the charging procedure is always terminated by the vehicle,
not by the wallbox. The EVSE 803/813 only indicates that you can un-
plug the charging cable from the vehicle charging socket on the basis of
communication with the vehicle. Should the vehicle not be charged suf-
ficiently at this point, please contact your service partner for the vehicle.