COMPONENT

QUANTITY DESCRIPTION

Drilling template

1

Template for drilling the holes for wall mounting

Installation kit

1

Set of fixings for wall mounting, consisting of 5 x 60 

screws as well as matching wall plugs 8 x 40, 6 seal-

ing grommets for openings at the wall bracket 

Should one or more components be missing after unpacking, please contact your local 

distributor immediately: You can find the necessary contact details on page ii in 

this manual. 

Available accessories

ABL sells additional accessories for your eMH1 Wallbox. For the models of the EVSE 

803 and 813 series, the following components are available:

DESIGNATION

MODEL NUMBER

QUANTITY

 

Mounting pole*  

For mounting all eMH1 Wallbox mod-

els with or without bracket  

Dimensions: 1600 x 280 x 70 cm  

Weight: 2,000 g

* does not include the wallbox pictured

STEMH10

1

Please contact your local distributor if you require additional information about these 

components or would like to place an order.

WARNING!   

Please note that the do-it-yourself installation of accessory components is 

not permitted: Please contact a qualified contractor or arrange installation 

with your local distributor.

Please also visit our website at ... 

www.abl.de

 

You will find further information about our products and our entire range there.

Summary of Contents for eMH1 WALLBOX

Page 1: ...Wallbox eMH1 VERSION EMH1 803 813 2017 10 20 ARTICLE NO 0301411_b Installation and operating manual EVSE 803 813...

Page 2: ...Bayerische Elektrozubeh r GmbH Co KG Albert B ttner Stra e 11 91207 Lauf Pegnitz Germany Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 Web www abl de Mail info abl de Customer Support Phone 49 0 9123 18...

Page 3: ...Package contents and unpacking 5 Available accessories 6 Installation and power supply connection 7 Prerequisites for the mounting site and installation 7 Preparation and mechanical installation 8 El...

Page 4: ...Checking the internal RCCB 17 Taking the device out of operation 18 Appendix 20 Technical specifications 20 Standards guidelines 20 Trademarks 21 CE certification and compliance declaration 22 Glossar...

Page 5: ...ion itself or to other electric devices Ac tions marked with this symbol must be carried out with special care PLEASE NOTE Sections marked with this symbol draw attention to further important in forma...

Page 6: ...s been otherwise damaged Please pay particular attention to the following points Read this manual carefully Keep this manual in a safe place where all users can always access it Heed all warnings Foll...

Page 7: ...x is intended for connection to and operation on 230 or 230 400 V 50 Hz mains power only Power supply cables may be installed below or above the wall surface The cable should enter the device via the...

Page 8: ...f the eMH1 are designed for the shortest possible charging times We place the highest value on user safety in all our products Almost all eMH1 Wallbox models therefore feature an internal residual cur...

Page 9: ...urrent detector three phase charging output 11 kW EVSE 813 230 V 50 Hz 32 A Identical to the EVSE 803 model variant but with a charging output of 7 2 kW CAUTION The information and technical specifica...

Page 10: ...lbox For the models of the EVSE 803 and 813 series the following components are available DESIGNATION MODEL NUMBER QUANTITY Mounting pole For mounting all eMH1 Wallbox mod els with or without bracket...

Page 11: ...r The wallbox must be installed where it is freely accessible to all authorized users Ideally the mounting site should already provide connection to the power supply If not a separate supply must be i...

Page 12: ...vehicle comfortably with the charging connector of the eMH1 The cable must not under any circumstances be strained when connected to the vehicle Preparation and mechanical installation After determin...

Page 13: ...illing template 1 Place the included drilling template vertically on the chosen mounting surface Use a spirit level if required CAUTION Check the measurements on the drilling template with a calibrate...

Page 14: ...e wall bracket in position using the included 5 x 60 torx headed screws 8 Seal the openings on the wall bracket with the included sealing grommets Electrical installation of your the wallbox The elect...

Page 15: ...L3 Neutral Blue N Protective earth Green Yellow PE DANGER The above color coding is not internationally standardized Should the in dividual wires in the power supply cable be color coded differently p...

Page 16: ...aker RCCB during vehicle charging This circuit breaker is especially required in cases where your electric vehicle does not provide any DC fault current protection itself You can find information abou...

Page 17: ...up into a compact shape and store it in a way that prevents it from being damaged by external mechanical forces Although the cable and connector are de signed to withstand high mechanical stresses yo...

Page 18: ...blue LED will be illuminated continuously while the con nection between wallbox and vehicle is being established When the charging procedure begins the blue LED will be extinguished and the green LED...

Page 19: ...e illuminated continuous ON flash be extinguished continuous OFF During normal operation the following operating states are shown Left LED Right LED DESCRIPTION OFF flashes every 5 seconds The wallbox...

Page 20: ...e vehicle If the error recurs the indicator LEDs continue to show the error code No charging occurs in this operating state CAUTION If the wallbox continues to show error messages during operation wit...

Page 21: ...quence The wallbox detects a malfunc tion All errors shown by the indicator LEDs relate to vehicle based functions see page 16 The wallbox re initiates the charging procedure ev ery 30 seconds Should...

Page 22: ...k the pivot lever of the internal RCCB if present into the 0 position connection to the power supply is interrupted 3 Lock the cover shield again Now the EVSE 803 813 cannot be used for charging To de...

Page 23: ...bage collection but must be taken to a collection point for electrical electronic waste Please observe all current national and regional legal regulations You can get further information from your mun...

Page 24: ...meter Control Customization internal RS485 interface Terminal block up to 6 mm2 up to 6 mm2 Operating temperature 30 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensati...

Page 25: ...ctive charging systems for electric vehicles Part 22 AC charging station for electric vehicles HD 60364 7 722 2012 Low voltage installations Part 7 722 Power supply for electric vehicles Classes of pr...

Page 26: ...eviations from the wider eMobility area ABBREVIATION DESCRIPTION MEANING BEV Battery Electric Vehicle Electric vehicle 100 electric use DC RCM Direct Current Residual Current Monitor Monitoring device...

Page 27: ...structions must always be left to a qualified electrical contractor who will connect the device to the local power supply You may however carry out the mechanical installation of the wallbox and drill...

Page 28: ...provisions ABL provides the legally prescribed guarantee period as well as a warranty of the same duration for the country in which the product was purchased Should the product be operated in another...

Page 29: ...persons or force majeure Any assumed guarantees including a guarantee of marketability or suitability for spe cific uses are restricted to the warranty period Disposal advice The crossed out trash ca...

Page 30: ...Albert B ttner Stra e 11 D 91207 Lauf Pegnitz Tel 49 0 9123 188 0 Fax 49 0 9123 188 188 info abl de www abl de ABL SURSUM Bayerische Elektrozubeh r GmbH Co KG MADE IN GERMANY...

Reviews: