background image

preparatIons, InstallatIon and takIng Into operatIon

12

5.  Fix the mounting plate in position with 

a screwdriver (TX40 bit) and the wafer 

head screws (8 x 60) included.  

 

 

PLEASE NOTE:

 In case the power 

supply enters from the rear, you must 

first thread the cable through the 

opening in the connection area in the 

lower third of the mounting plate be-

fore screwing the plate into position.

6.  For the cable to enter from the top, you 

must install the power supply such that 

it is inserted into the connection area 

from above and can be fixed using its 

allocated strain relief.  

 

 

 

PLEASE NOTE:

 The strain relief is not 

required if the power supply enters 

from the rear. 

 83 

7.  Now open the housing cover of 

the wallbox using the triangular 

key supplied and flip it towards the 

front. 

    

 

PLEASE NOTE: 

Take special care with 

this and protect the housing cover 

against scratching and other external 

damage. If possible, only remove the 

protective film from the housing cover 

just before completing installation.

8.  Use the screwdriver to loosen the 

TX20 screw holding the internal elec-

tronic components cover in place and 

remove it. Keep the screw in a safe 

place. 

Summary of Contents for 3W2205

Page 1: ...VERSION EMH3 2016 10 28 IM ARTICLE NO 0301592 Installation manual Wallbox eMH3...

Page 2: ...Bayerische Elektrozubeh r GmbH Co KG Albert B ttner Stra e 11 91207 Lauf Pegnitz Germany Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 Web www abl de Mail info abl de Customer Support Phone 49 0 9123 18...

Page 3: ...eration 6 Introducing the product 6 Unpacking and components included 6 Identifying your model variant 7 General requirements of the installation site 8 Requirements for the power supply 9 Mechanical...

Page 4: ...cations 23 Scale drawings and dimensions 25 Contact chartType 1 Type 2 27 Guidelines Norms 27 CE certification and compliance declaration 28 Glossary Definitions 28 Trademarks 28 Intellectual Property...

Page 5: ...charging socket and 22 kW max output 3W2209 eMH3 Single with charging socket and shutter 22 kW max output 3W2214 eMH3Twin with charging sockets and 2 x 11 kW or 1 x 22 kW max output 3W2217 eMH3 Twin...

Page 6: ...care PLEASE NOTE Sections marked with this symbol draw attention to further important in formation and special features that are necessary for the reliable operation of the device Actions marked with...

Page 7: ...d at all times No liquids or objects or receptacles containing liquids must be placed on the hous ing Please note that additional overvoltage protection may be required depending on the connected vehi...

Page 8: ...tact ABL technical support Always contact ABL technical support if the housing has been damaged mechanically the housing cover has been removed or can no longer be closed or locked sufficient protecti...

Page 9: ...allbox should not be installed in areas of high pedestrian traffic Installation along thoroughfares and marked escape routes should be especially avoided Never install the wallbox in a confined space...

Page 10: ...ng cover allow you to check the current operating status at any time Should a malfunction occur you can identify the cause by its specific LED error code without having to open the housing After being...

Page 11: ...32 A Single charging station with fixed charging cable according to IEC 62196 2 Type 2 integrated factory deactivated RFID module for access control internal Type A RCCB internal DC fault current dete...

Page 12: ...rging station with two integrated charg ing sockets according to IEC 62196 2 Type 2 with locking mechanisms for separately avail able charging cables Type 2 to Type 2 or Type 2 to Type 1 integrated fa...

Page 13: ...gineered for operation in high ambient tempera tures However it must be ensured that the maximum operating temperature is not exceeded through external influences such as direct sunlight or similar Th...

Page 14: ...integrated RFID module The necessary procedure is described in section Deactivating and reactivating of the charging function via RFID on page 14 of the user manual for the ABL Wallbox Please always e...

Page 15: ...r even death Proceed as follows to drill the holes using the mounting plate 1 Ensure that a sufficiently dimensioned power supply is available at the desired instal lation site Otherwise a power suppl...

Page 16: ...inserted into the connection area from above and can be fixed using its allocated strain relief PLEASE NOTE The strain relief is not required if the power supply enters from the rear 83 7 Now open th...

Page 17: ...into the respective opening in the mounting plate this already protects the wallbox from falling 11 Now fix the wallbox to the mounting plate using the screwdriver TX25 bit and the four 6 x 25 screws...

Page 18: ...onnected as follows DESIGNATION CONNECTION CODING Current carrying conductor phase 1 L1 Current carrying conductor phase 2 L2 Current carrying conductor phase 3 L3 Neutral N Protective earth PE The tw...

Page 19: ...rovide a lower or higher charging current the preset current for the wall box must be adjusted accordingly before you replace the electronic components cover and then take the wallbox into operation P...

Page 20: ...ical installation you must check the correct functioning of the ABL Wallbox for operation and resolve any malfunctions or installation errors that may have occurred Proceed as follows to take the ABL...

Page 21: ...Possible cause Suggested solution LEDs are not functioning The wallbox does not have a power supply First check the internal RCCB s Should power be interrupted in the domestic supply Check the upstre...

Page 22: ...cted a disallowed operat ing state during the initial or periodic self test The green LED flashes three times then the blue LED flashes once the red LED is continuously ON Solution In both cases switc...

Page 23: ...ashes twice then the blue LED flash es twice the red LED is continuously ON Solution The wallbox automatically reinitiates the charging procedure every 60 sec onds Should the error continue to occur c...

Page 24: ...current The green LED flashes four times every fourth time the blue LED also flashes the red LED is continu ously ON Solution The wallbox automatically reinitiates the charging procedure every 60 sec...

Page 25: ...of operation see Tak ing the product out of and back into operation on page 22 and contact the special ist electrical contractor who has performed the installation to resolve the error 200 ms 200 ms...

Page 26: ...installation of the eMH3 must always be carried out by a qualified electrical contractor To take the wallbox into operation again at a later time please proceed as follows 1 Switch on the upstream MC...

Page 27: ...ection devices Type A 30 mA RCCB and DC RCM I n d c electronic DC fault current detector 6 mA Control Customization Internal RS485 and USB interfaces no user access Operating temperature 30 C to 50 C...

Page 28: ...cc with IEC62196 2 2 pcs Circuit protection devices Type A 30 mA RCCB and DC RCM I n d c electronic DC fault current detector 6 mA Control Customization Internal RS485 and USB interfaces no user acces...

Page 29: ...awings and dimensions The ABL Wallbox is delivered fully assembled and quality checked All measurements in the following elevations are in mm Mounting plate and wallbox Wallbox 3W2205 200 254 83 477 9...

Page 30: ...Appendix 26 Wallboxes 3W2207 and 3W2209 Wallboxes 3W2214 3W2217 and 3W4401 194 400 492 134 194 400 492 134...

Page 31: ...ive charging systems for electric vehicles Part 1 General requirements IEC TS 61439 7 2014 Part 7 Switching device combinations for specific applications such as marinas campgrounds market squares cha...

Page 32: ...or download Glossary Definitions In the following important abbreviations and terms used in this manual are explained Abbreviation Description Meaning DC Direct Current Direct current DC RCM Direct Cu...

Page 33: ...ossible misinformation contained in these instructions This manual in its entirety or in parts must not be reproduced stored electronically or otherwise transmitted electronically electrically mechani...

Page 34: ...Albert B ttner Stra e 11 D 91207 Lauf Pegnitz Ph 49 0 9123 188 0 Fax 49 0 9123 188 188 info abl de www abl de ABL SURSUM Bayerische Elektrozubeh r GmbH Co KG MADE IN GERMANY...

Reviews: