29
Setting an acceptance delay
Control 10 makes it possible to set an acceptance delay. By acceptance delay is meant the
time a button has to be pressed before a result is reached. The acceptance delay can be
set in 6 steps (
---
,
1
,
2
,
3
,
4
,
!
).
---
= no delay time and
!
= maximum delay time (0.5 second).
Do as follows:
1. Press
P
and
2
at the same time. The indication lamp for the current level are now lit.
2. Press a button,
---
,
1
,
2
,
3
,
4
,
!
to choose delay time.
3. The indication lamp for programming flashes green to show that the operation is
complete.
Setting an acceptance delay
Press
P
+
2
,
choose setting.
---
= no delay time and
!
= maximum delay time (0.5 second).
Default setting: Acceptance delay = OFF (0 sec).
Creating an automatic sequence (Macro)
Your Control 10 is able to send sequences of codes. When you press
one
button, Control
10 automatically carries out what is equivalent to pressing several buttons. One available
application for instance is muting the TV at the same time as you answer the telephone.
Your Control 10 can also be programmed to change levels and it remembers how long a
button should transmit. The transmission of a sequence can be terminated at any time by
pressing another optional button. When a sequence is programmed your Control 10
transmits at the same time what is already on the button. Max. 25 seconds and 48 button
presses per sequence can be programmed.
NOTE! The button used to store the sequence must not be part of the sequence.
1. Press
P
and
!
at the same time. The indication lamp for the current level are now lit.
2. Press
1
.
3. Press the buttons which should be used for the sequence.
4. Choose the level where you want the sequence to be.
5. Press
P
and
!
at the same time. The indication lamp for level B and the current level
are now lit.
6. Press
2
.
7. Choose the button
X
where you want the sequence to be stored.
8. The indication lamp for programming flashes green to indicate that the operation is
complete.
Creating an automatic sequence (Macro)
Press
P
+
!
,
1
,
create the sequence
,
choose level
,
P
+
!
,
2
,
choose button
X
.
Max 25 seconds per press, 48 presses