EN - 4
2 Product Description
MT/AUT/AUT RAB
2.3 Technical Data
Transport and storage
- 25 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient temperature
Type of use
automatic
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Wire types
commercially available round wires
Voltage rating
141 V peak value
Protection type of the machine side
connections (EN 60 529)
IP2X
Tab. 2
General torch data (EN 60 974-7)
Type
Type of
cooling
Load
Duty
cycle
Wire
ø
Gas flow Cooling data
dual
circiut
DC
Impulse
Supply
temp
Flow Flow
pressure
CO
2
M21
M21
max.
min
min.
max.
MT
A
A
%
mm
l/min
°C
l/min
bar
bar
452 W
liquid
500
500
325
100
1,0 - 1,6 10 - 20
50
1,0
2
3,5
452 DW
liquid
450
450
300
100
1,0 - 1,6 10 - 20
50
1,0
2
3,5
645 W
liquid
650
600
450
100
1,0 - 1,6 10 - 20
50
1,0
2
3,5
Tab. 3
Product-specific torch data (EN 60 974-7) ABIMIG
®
MT