MF1 rear
7 Operation
EN - 15
7 Operation
1
Switch on the robot control.
7.1 Control elements
DANGER
Shortness of breath and poisoning caused by inhaling phosgene gas
When welding workpieces that have been degreased with chlorinated solvents, phosgene gas is formed.
• Do not inhale fumes and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the welding area.
NOTICE
• The MF1 rear may only be operated by qualified personnel (in Germany see TRBS 1203).
• As the MF1 rear is integrated into a welding system, the operating instructions of the welding
components, such as welding torch and power source, must be observed during operation.
1
CAT socket
2
Control lead port
3
Gas test trigger
4
Inching trigger
Fig. 7
Overview of control elements
1
2
4
3
Symbol
Description
Control lead port
. Connect the connection plug to the control lead port
to establish signal transmission.
Optional: only when using safety cut-out CAT-2.
Connect the CAT socket
to the helix cable of the CAT emergency stop safety cut-out. The integrated control lead
will transmit the signal to peripheral devices.
Gas test trigger (black)
. Press the trigger: gas flows. Check the gas volume.
Inching trigger (green)
. Press the trigger once: wire is fed.
Summary of Contents for MF1-Rear
Page 74: ...ES 20 Notas MF1 Rear Notas ...