iFEED 742
6 Putting into operation
EN
-
13
7
Open the cover.
8
Guide the welding power cable
through the slot
in the housing.
9
Fasten the eye of the welding power cable
using the M10 × 16 hexagon
nut
, the lock washer
and check that it is firmly seated.
10
Close the cover.
6.2 Welding torch cable assembly
1
Depending on the version, connect the control leads to connections
or
and connect to the
welding torch.
2
Connect the compressed air hose to the compressed air connection
.
3
Connect the shielding gas hose to the shielding gas connection
.
4
Connect the RPC connector plug of the welding torch to the RPC connection
Fig. 5
Connecting the welding torch cable assembly to the device
A
Shielding gas connection
B
Compressed air connection (cleaning)
C
Welding torch control lead connection
D
RPC connection
E
MPP control lead connection (optional)
C
E
B
A
D