FES-200 W3
5 Functional Description
EN - 9
Harmful fumes are produced during the welding process. A permanent filter located in the filter housing
removes the welding fume particles from the sucked air. The cleaned air is led back into the work area via
the exhaust box
If the minimum volume flow is not reached, the manometer
indicates a high value and an acoustic
signal sounds. Then the filter must be cleaned with compressed air. During the dedusting procedure, the
exhaust fume deposits are removed from the filter elements and the filter is refreshed.
The separated dust is collected in a dust collecting drawer
The FES-200 W3 is equipped with an automatic Start-Stop system. Use the current clamp to switch on
automatically the fume extraction system by fixing it to the cable assembly of the welding device.
6 Putting into operation on page EN-14
The rotary switch
is used to switch on and off the fume extraction system.
1
Rubber gasket
2
Turbine
3
Fastening screws
4
Compressed air connection for dedusting
5
Filter cartridge
6
Extraction hose connection
7
Seal plug
8
Dust collecting drawer
9
Knurled nut
10
Manometer
11
Rotary switch (I-0-Auto)
12
Exhaust box
13
Power cable connection
14
Fuse 250 V, 2.5A delay-action
15
Current clamp connection
16
Counter nut
Fig. 2
Functional Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
NOTICE
• The dust collecting drawer
must be emptied before and after each dedusting of the filter.
• After each use, the dust collecting drawer must be checked.
• In case of a filling level of 2/3 or more, the dust collecting drawer must be emptied according to the
regulations.