FES-200 W3
5 Functional Description
EN - 11
13
Dispose of the dust collecting bag and the disposable cloth according to the local regulations.
5.2 Filter dedusting (dedusting by rotation)
DANGER
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, mounting, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Close off the compressed air supply.
• Pull the mains plug.
CAUTION
• Before performing any maintenance and cleaning work, the necessary safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
locally filtered forced ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Personal protective equipment consists of protective clothing, safety goggles, class P3 respiratory
mask, safety gloves and safety shoes.
• Nobody without personal protective equipment may stay near the dust collecting drawer when
emptying it.
NOTICE
• This procedure must be carried out when the system is not in operation.
• Use only dry and oil-free compressed air (max. 4 bar).
1
Seal plug
2
Filter dedusting (dedusting by rotation)
3
Compressed-air connection
4
Valve lever
Fig. 4
Dedusting the filter
1
2
3
4