FES-200 W3
5 Functional Description
EN - 13
Proceed as follows:
Fig. 2 Functional Description on page EN-9
1
Put the fume extraction system on the floor.
2
Switch off the fume extraction system by actuating the rotary switch
.
3
After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
4
Unscrew the fastening screws
from the cover and lift it off.
5
Place the cover carefully on the fume extraction system so that the filter cartridge points upwards.
6
Press the rotation mechanism carefully downwards.
7
Place the dust collecting bag completely over the filter cartridge
8
Loosen the filter cartridge
by turning it to the left (counter-clockwise direction).
CAUTION
• Before performing any maintenance and cleaning work, the necessary safety measures must be
taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
locally filtered forced ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask
class P3, protective gloves and safety shoes.
• Nobody without personal protective equipment may stay near the dust collecting drawer when filling
the separated dust into it.
• It is not allowed to dedust the filter cartridge using compressed air.
NOTICE
• A filter change must be carried out if, after multiple dedusting, a vacuum of >180 mbar is still reached,
and no other error or reason can be detected.
• This procedure must be carried out when the system is not in operation.
1
Place the cover on the fume extraction
system
2
Pull the dust collecting bag over the filter
cartridge
3
Loosen the filter cartridge
Fig. 5
Changing the filter