EN - 14
6 Putting into operation
FES-200 W3
9
Remove the filter cartridge
and slide it completely into the dust collecting bag.
10
Close the dust collecting bag tightly.
11
Clean the sealing surface of the cover using a damp disposable cloth.
12
Dispose of the dust collecting bag and the disposable cloth according to the local regulations.
13
Place the pin and the sponge rubber seal of the new filter cartridge
into the locking mechanism.
14
Press the filter cartridge
slightly downwards into the locking mechanism.
15
Fix the filter cartridge
by turning it to the right (clockwise direction).
16
Make sure that the filter cartridge is fixed on all locking points.
17
Insert the cover with the mounted new filter cartridge into the fume extraction system.
18
Tighten the fastening screws
.
6 Putting into operation
4
Closing the dust collecting bag tightly
5
Inserting a new filter cartridge into the
locking
6
Checking the locking points
Fig. 6
Removing the filter cartridge
NOTICE
• When mounting the new filter cartridge, make sure to touch only the bottom of the filter. Otherwise the
filter material may become damaged, which will destroy the filter cartridge.
NOTICE
• Make sure that the cables and hoses are not kinked, caught or damaged.
DANGER
Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, mounting, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Pull the mains plug.
NOTICE
• The fume extraction system must be mounted on a plane surface near the work area.