6 Putting into operation
6.1 Transport and installation
1
Heat exchanger (finned radiator), 2-row
2
Coolant supply (blue)
3
Coolant return (red)
4
Coolant container
5
Motor with fan
6
Centrifugal pump
Fig. 7
Overview of the coolant circuit
1
6
2
3
4
5
DANGER
Risk of injury due to unexpected start-up
The following instructions must be followed during all maintenance, servicing, assembly, disassembly, and repair work:
• Switch off the power source.
• Disconnect all electrical connections.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Please take note of the following instructions:
3 Product description on page EN-5
• The system may only be installed and put into operation by qualified personnel (in Germany see TRBS 1203).
• Components must only be used in environments with sufficient ventilation.
• The connection (serial or parallel connection) of several cooling units can result in material damage.
• Make sure that the cooling unit is filled with cooling liquid before it is put into operation.
• The coolant pump must never run dry as this will destroy the pump and render the warranty invalid.
CAUTION
Risk of injury
Physical injury due to falling devices and mounting parts.
• Avoid abrupt lifting and setting down.
• Do not lift the components over persons or other devices.
• Transport the components in an upright position only and with an empty coolant container to prevent coolant leakage.
• Wear your personal protective equipment: safety shoes with steel toe caps, protective work gloves, safety helmet, ear
protectors.
• Send bystanders out of the danger zone.
• Note the weight of the individual components.
3 Product description on page EN-5