EN - 8
6 Putting into operation
BRS-LCi
5.1 Cleaning station sub-assembly
6 Putting into operation
1
S4 Inductive proximity switch (stroke on top)
2
S2 Inductive proximity switch (clamp - open)
3
Y2 5/2-way valve for clamping device (clamp - unscrew) and
motor (on - off)
4
Y1 5/2-way valve for milling cutter stroke (bottom - top)
5
Y3 5/2-way valve for injection unit
6
S3 Inductive proximity switch (motor rotates)
7
Harting plug
8
S1 Inductive proximity switch (stroke on top)
Fig. 3
Cleaning station sub-assembly
1
3
8
7
6
4
5
2
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Cut off the gas supply.
• Pull the mains plug.
NOTE
• The cleaning station may only be put into operation by trained personnel.
• Make sure that the cleaning process is not impaired by the collecting tray and the bottle holder.