Problem
Cause
Solution
Torch necks gets hot • Contact tip/tip adapter not tightened
• Power connections loose on the torch
side and toward the work-piece
• Check and tighten
• Check and tighten
Wire burned solid in
the contact tip
• Wrong parameters set
• Contact tip worn out
• Check or correct setting
• Replace
Irregular wire feed
• Contact tip and wire diameter not
matched
• Wrong contact pressure set on the wire
feed unit
• Replace contact tip
• Correct as specified by
manufacturer
Arc between gas
nozzle and work-
piece
• Spatter bridge between contact tip and
gas nozzle
• Clean and spray gas nozzle
interior
Erratic arc
• Contact tip not matched to the wire
diameter or contact tip diameter
enlarged
• Wrong welding parameters set
• Check contact tip
• Correct welding parameters
Pore formation
• Strong spattering in the gas nozzle
• Insufficient or missing gas cover
• Air currents blowing shielding gas
away
• Clean gas nozzle
• Check gas cylinder contents and
pressure setting
• Shield welding area with partitions
Tab. 8