EN - 14
9 Maintenance and cleaning
ABIROB
®
350GC
9.1 Torch neck
1
Remove gas nozzle
2
Remove welding spatter and spray gas nozzle using the
ABICOR BINZEL
anti-spatter agent.
3
Check wearing parts for visible damage and replace them, if required.
4
If neck liner is present, replace it when worn or soiled.
5
Clean separating point and O-rings with silicone-free sealing grease.
9.2 Wire guide
1
Unscrew the cable assembly
on the machine side and bring it into a
straight position.
2
Pull out wire guide
.
3
Clean wire feed hose from both sides with compressed air.
4
Slide wire guide
into wire feed unit and secure it with the spigot nut
.
NOTE
• The maintenance intervals given are recommended values and refer to
single-shift operation.
• Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
• Always wear your personal protective clothing when performing
maintenance and cleaning work.
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable
protective clothing, in particular safety goggles.