Capacity:
200 L @ 30 ˚C , 80% RH
Operating Relative Humidity Range:
36%-90%
Amperage Usage:
12.2 Amps
Sound Level:
59 dBa
Airflow @ 0.0” SP:
520CFM
COP:
2.8 L/kWh
Power Supply:
220/240 VAC, 50 Hz, 12.2 Amps
Dimensions LxWxH:
31.5” x 19.3” x 17.8”
Operating Temp. Range:
33-105°F
Refrigerant:
R290
Outlet Requirement:
15 Amp, 3 Prong, GFCI
ETL Listed:
Yes
Specifications
Accessories
Items Included in Box:
·
ATTIC
DH200
Dehumidifier
·
ATTIC
DH200
Installation
Instructions
·
ATTIC
DH200
Leveling
Feet
Installation
Precaution
Removing
the
compressor
shipping
support
Ensure
to
remove
a
compressor
transport
tie
after
releasing
it
.
If
you
don’t
,
it
may
cause
the
transmission
of
unnecessary
vibration
to
the
unit
'
s
frame
.
It
may
be
necessary
to
remove
the
refrigeration
and
the
compressor
during
shipping
.
A
plastic
tie
is
normally
secured
on
the
unit’s
frame
.
Remove
the
wrap
tie
by
simply
cutting
it
.
Once
you
remove
it
,
you
will
then
need
to
insert
plugs
into
the
holes
.
Precaution
during
Installation
The
equipment
is
designed
to
be
installed
indoors
and
should
be
protected
from
flooding
and
rain
.
•
The
unit
should
be
installed
in
enough
spaces
for
maintenance
purposes
.
•
Check
and
ensure
that
the
air
is
not
discharged
at
people
•
If
you
choose
to
use
the
unit
near
a
water
source
,
ensure
that
it
is
protected
from
water
splashes
.
Also
,
you
cannot
use
the
dehumidifier
as
a
table
or
a
bench
.
•
Do
not
place
the
unit
on
a
structural
building
without
sound
and
vibration
absorbers
.
•
You
will
need
to
use
a
drain
pan
,
and
a
float
switch
that
should
be
placed
under
the
unit
if
it
is
installed
above
a
living
area
or
an
area
under
which
water
leakage
may
occur
.
•
Consideration
for
the
location
The
most
important
thing
you
should
consider
when
installing
the
dehumidifier
is
that
you
should
allow
enough
space
for
clearance
.
Space
should
be
sufficient to allow for running both
duct works.
.
There
should
be
enough
space
to
prevent
airflow
obstruction
or
filter
change.
.
•
•
You
will
need
to
remove
the
side
panel
so
that
you
have
enough
space
during
clearance
.
The
dehumidifier
should
be
situated
in
an
area
where
the
length
of
the
cord
is
9
'
away
from
115
VAC
with
a
circuit
capacity
of
15
Amp.
.
•
The
unit
should
also
be
located
in
an
area
where
it
can
easily
be
connected
to
the
source of power.
.
Make
use
of
a
backdraft
damper
to
discharge
the
ATTIC
DH100
.
This
should
happen
whenever
you
connect
it
to
the
supply
ducting
system
.
The
damper
will
prevent
the
air
from
flowing
through
the
ATTIC
DH
200
when
not
operating
.
Thus
the
location
of
the
dehumidifier
should
be
chosen
so
as
to
allow
for
installing
the
accessory.
.
•
•
Also
,
ensure
you
allow
for
proper
drainage
and
routing
.
It
makes
it
easier
to
drain
the
pipes
.
•
3