Capacity: 

200 L @ 30 ˚C , 80% RH

Operating Relative Humidity Range: 

36%-90%

Amperage Usage:

 

12.2 Amps

Sound Level: 

59 dBa

Airflow @ 0.0” SP: 

520CFM

COP: 

2.8 L/kWh

Power Supply: 

220/240 VAC, 50 Hz, 12.2 Amps

Dimensions LxWxH: 

31.5” x 19.3” x 17.8”

Operating Temp. Range: 

33-105°F

Refrigerant: 

R290

Outlet Requirement: 

15 Amp, 3 Prong, GFCI

ETL Listed: 

Yes

Specifications

Accessories

Items Included in Box:

· 

ATTIC

 

DH200

 

Dehumidifier

· 

ATTIC

 

DH200

 

Installation

 

Instructions

· 

ATTIC

 

DH200

 

Leveling

 

Feet

Installation

Precaution

Removing

 

the

 

compressor

 

shipping

 

support

Ensure

 

to

 

remove

 

a

 

compressor

 

transport

 

tie

 

after

 

releasing

 

it

If

 

you

 

don’t

it

 

may

 

cause

 

the

 

transmission

 

of

 

unnecessary

 

vibration

 

to

 

the

 

unit

'

s

 

frame

It

 

may

 

be

 

necessary

 

to

 

remove

 

the

 

refrigeration

 

and

 

the

 

compressor

 

during

 

shipping

A

 

plastic

 

tie

 

is

 

normally

 

secured

 

on

 

the

 

unit’s

 

frame

Remove

 

the

 

wrap

 

tie

 

by

 

simply

 

cutting

 

it

Once

 

you

 

remove

 

it

you

 

will

 

then

 

need

 

to

 

insert

 

plugs

 

into

 

the

 

holes

.   

Precaution

 

during

 

Installation

 

The

 

equipment

 

is

 

designed

 

to

 

be

 

installed

 

indoors

 

and

 

should

 

be

 

protected

 

from

 

flooding

 

and

 

rain

The

 

unit

 

should

 

be

 

installed

 

in

 

enough

 

spaces

 

for

 

maintenance

 

purposes

Check

 

and

 

ensure

 

that

 

the

 

air

 

is

 

not

 

discharged

 

at

 

people

If

 

you

 

choose

 

to

 

use

 

the

 

unit

 

near

 

a

 

water

 

source

ensure

 

that

 

it

 

is

 

protected

 

from

 

water

 

splashes

.

Also

you

 

cannot

 

use

 

the

 

dehumidifier

 

as

 

a

 

table

 

or

 

a

 

bench

.

Do

 

not

 

place

 

the

 

unit

 

on

 

a

 

structural

 

building

 

without

 

sound

 

and

 

vibration

 

absorbers

.

You

 

will

 

need

 

to

 

use

 

a

 

drain

 

pan

and

 

a

 

float

 

switch

 

that

 

should

 

be

 

placed

 

under

 

the

 

unit

 

if

 

it

 

is

 

installed

 

above

 

a

 

living

 

area

 

or

 

an

 

area

 

under

 

which

 

water

 

leakage

 

may

 

occur

.   

Consideration

 

for

 

the

 

location

The

 

most

 

important

 

thing

 

you

 

should

 

consider

 

when

 

installing

 

the

 

dehumidifier

 

is

 

that

 

you

 

should

 

allow

 

enough

 

space

 

for

 

clearance

Space

 

should

 

be

 

sufficient to allow for running both

 

duct works.

.

There

 

should

 

be

 

enough

 

space

 

to

 

prevent

 

airflow

 

obstruction

 

or

 

filter

 

change.

You

 

will

 

need

 

to

 

remove

 

the

 

side

 

panel

 

so

 

that

 

you

 

have

 

enough

 

space

 

during

 

clearance

The

 

dehumidifier

 

should

 

be

 

situated

 

in

 

an

 

area

 

where

 

the

 

length

 

of

 

the

 

cord

 

is

 

9

away

 

from

 

115

 

VAC

 

with

 

a

 

circuit

 

capacity

 

of

 

15

 

Amp.

The

 

unit

 

should

 

also

 

be

 

located

 

in

 

an

 

area

 

where

 

it

 

can

 

easily

 

be

 

connected

 

to

 

the 

source of power.

.

Make

 

use

 

of

 

a

 

backdraft

 

damper

 

to

 

discharge

 

the

 

ATTIC

 

DH100

This

 

should

 

happen

 

whenever

 

you

 

connect

 

it

 

to

 

the

 

supply

 

ducting

 

system

The

 

damper

 

will

 

prevent

 

the

 

air

 

from

 

flowing

 

through

 

the

 

ATTIC

 

DH

 

200

 

when

 

not

 

operating

Thus

 

the

 

location

 

of

 

the

 

dehumidifier

 

should

 

be

 

chosen

 

so

 

as

 

to

 

allow

 

for

 

installing

 

the

 

accessory.

Also

ensure

 

you

 

allow

 

for

 

proper

 

drainage

 

and

 

routing

It

 

makes

 

it

 

easier

 

to

 

drain

 

the

 

pipes

.

3

4

Summary of Contents for Living Environment Series

Page 1: ...er User sManual Note as we keep upgrading our product we reserve the right to modify the product without natice in advance Abestorm Solutions INC Living Environment Series Add Berlin Tel 44 20 81243974 Email www abestorm com ...

Page 2: ...f the unit Model Number ATTIC DH200 Serial Number Date of Number For additional questions concerning your dehumidifier the following options are available Call abestorm at 44 20 81243974 Email sales abestorm com 1 2 Are you thinking about installing and operating the ATTIC DH200 device If yes reading these instructions will help you If you want to operate or maintain the equipment you may also nee...

Page 3: ... a water source ensure that it is protected from water splashes Also you cannot use the dehumidifier as a table or a bench Do not place the unit on a structural building without sound and vibration absorbers You will need to use a drain pan and a float switch that should be placed under the unit if it is installed above a living area or an area under which water leakage may occur Consideration for...

Page 4: ...f backdraft devices are such as the hot water heater are present in the place that needs to be dehumidified it is important that the manufacturer or certified service provider completes the installation It may be necessary to slightly pressurize and or dehumidify the room if the dehumidifier is to be located in a smaller room that is separate from the main area that requires dehumidification The p...

Page 5: ...ng utilized 4 Temperature The T button changes the temperature reading on your remote The remote comes from the factory in Celsius Press this button once to switch to Fahrenheit 5 Continuous Press this button to switch the unit into continuous mode CONT will appear on the display screen 6 Drain Pump Use this button if the unit will not be used for an extended period of time This button will remove...

Page 6: ...store for a longer duration you will need to go through the following steps before using it 1 2 3 4 5 Switch off the unit and give it some time to dry Complete the first three steps in the pump and reservoir cleaning Ensure the power chord is well wrapped and secured The filter mesh should also be covered It should be stored in a dry and clean space Unit Diagram Be sure to secure the ducting with ...

Page 7: ...above 33 If error still displays check sensor Decrease the room temperature so it is within operating range below 105 If error stille displays check the sensor Identify all sources connected to outlet and confirm source of trip If it is dehumidifier contact technical support If not move dehumidifier to dedicated circuit for future use Replace Outlet Clean or Replace Outlet as necessary Reset or Re...

Page 8: ...mer s job to bring the unit to a certified repair center If this is not an option shipping will be arranged to bring the unit back to the Unipdry warehouse at the expense of the customer 4 After the unit has been received by Unipdry whether at a repair center or the warehouse an initial inspection will be completed if it is determined to be an invalid warranty claim see exclusions below unit will ...

Reviews: