Example:
To modify the heartbeat period to 1 hour, the command
0x0B020100000E10
should be sent.
Descripton:
(0x0B): set the parameter
(0x02): tith an ack token of 2
(0x01): heartbeat message period
(0x 00 00 0E 10): to a value of 3600s = 1 hour
7.6.2
Parameters for side operaton modes
Parameter
ID
Unit
Range
Descripton
periodic_pos_period
0x03
seco
nd
0, 900 i 604800
Period of the periodic positon report.
When set to 0, the reportng is disabled.
geoloc_method
0x06 none 0i4
Geolocaton policy used for the side operatng
modes:
0i WIFI
1i GPS
2i LPGPS (AGPS/GPS)
3i WIFIiGPS only (WIFI then GPS if WIFI fails in one
geolocaton cycle)
4i WIFIiLPGPS only (WIFI then LPGPS if WIFI fails in
one geolocaton cycle)
periodic_actiiitt_period
0x16
seco
nd
0,1800i86400
Period of the periodic activity report
The value must be a multiple of 6
When set to 0, the reportng is disabled
Example:
To modify the periodic positon period to 12 hours, the command
0x0B01030000A8C0
should be
sent.
Descripton:
(0x0B): set the parameter
(0x01): tith an ack token of 1
(0x03): periodic positon message period
(0x 00 00 A8 C0): to a value of 43200s = 12 hours
7.6.3
Parameters for GPS and low power GPS geolocaton modes
Parameter
ID
Unit
Range
Descripton
GPS
gps_timeout
0x09
seco
nd
30i300
Timeout for GPS scans before sending a GPS
tmeout message.
antenna
(1)
0x07
0i2
0: GPS PCB antenna
1: GPS ceramic antenna
2: automatc selecton betteen PCB and ceramic
antenna
Page 34 of 46
10th July 2019