10. RO Only Valve Operation

There is a 2 way wye located on the bottom of your RO 

housing. This can be used in several ways.  

First, it allows you access to the clean water coming 

out of the RO membrane before it is run through the DI 

filter. You should periodically test the TDS of this RO 

water to assess the health of your RO membrane.  

Depending on the TDS of your source water, your RO 

membrane may purify the water sufficiently for your 

cleaning application (abc recommends that TDS be 

at least 10 ppm or below for most window cleaning 

applications). If you, as the window cleaner, decide the 

RO only water is clean enough for your application, 

you can attach your pole tubing directly to the RO only 

valve and shut off the flow of water to the DI filter to 

preserve the life of your DI resin. 

When using a RO membrane, there is a spike of higher 

TDS water that passes through the membrane each 

time you start using it. Users that wish to avoid passing 

this higher TDS water through their DI resin can shut off 

the DI side of the wye. Open the RO only side, turn on 

the source water, run it for about 10-30 seconds, open 

the DI side again and then shut off the RO only side. 

Do not shut off both sides of the RO only wye if you are 

running a pump, as that could damage the system.

9. Producing Pure Water

Connect your WaterFed® pole to the end of the 

production water hose. Open the shut-off valve 

between the hose and the pole to allow water to flow 

through the pole and wash glass. Do not drink pure 

water made from your system. 

11. TDS (Total Dissolved Solids) Meter

Total Dissolved Solids are the particles dissolved within 

water that can lead to spotting on glass as the water 

evaporates. Your TDS meter measured the amount of 

dissolved solids by measuring the conductivity of the 

water.  

Push the “On” button on the TDS meter (included) – 

capture a small amount of your production water in 

the cap of the TDS meter to get a reading of the water. 

A TDS reading of 0 – 10 is acceptable for cleaning 

windows, specific conditions and results may vary. 

When measuring source water before pure water TDS 

levels, it is important to rinse out any source water with 

pure water to ensure accurate readings. Even a single 

drop of source water will cause the pure water’s TDS 

reading to be higher than it actually is. Read all sections 

before continuing for optimal system performance.  

Your TDS meter also has a thermometer which reads 

temperature. This can allow you to monitor the 

temperature of your feed water. RO membranes require 

more pressure to create the same amount of clean water 

as the temperature of the water gets colder. Running 

your system at feed water temperatures of less than 10 

degrees celsius (50 degrees fahrenheit) could result in 

low flow exiting the system.

Summary of Contents for SG2

Page 1: ...water approximately 10 000 gallons of water can be passed through the sediment carbon and DI filters before replacement filters are needed It is recommended that the sediment carbon and DI filters be...

Page 2: ...rew the wingnut at the top of the carbon filter cartridge Remove the carbon filter by first pulling top of the filter away from the frame removing it from top bolt Next lift up to remove the filter fr...

Page 3: ...new RO membrane into the housing by pushing it down and into the o rings on the bottom of the assembly Coat the o ring with molykote and insert into shelf on the top of the RO housing Insert the black...

Page 4: ...ressure before the RO housing to travel through the membrane and into the DI filter The RO housing is able to handle more pressure than the DI filter and the resulting pressure transfer can damage the...

Page 5: ...at could damage the system 9 Producing Pure Water Connect your WaterFed pole to the end of the production water hose Open the shut off valve between the hose and the pole to allow water to flow throug...

Page 6: ...ure proper mobility for your system Periodically check the electrical wiring and system for damage Test your GFCI by pushing the white button to test the shut off and the red button to reset the syste...

Page 7: ...microorganisms that might try to grow in your filters Always run your source water through the carbon filter before the RO membrane when flushing the filter abc strongly recommends flushing out the RO...

Page 8: ...y to misuse or abuse causing failure of the system The customer must contact abc Window Cleaning before attempting any repairs or modification to the system Failure to do so will void your warranty ab...

Reviews: