background image

MN1949 Analog I/O Option

Summary of Contents for OPT-MF-001

Page 1: ...MN1949 Analog I O Option ...

Page 2: ......

Page 3: ...1 General Information 2 Introduction 2 1 Analog I O option features 2 1 2 1 1 Installation 2 1 3 Input Output 3 1 Introduction 3 1 3 1 1 Slot selection and input output numbering 3 1 3 1 2 Analog inputs 3 3 3 1 3 Analog outputs 3 5 ...

Page 4: ...ii Contents MN1949WEN ...

Page 5: ...itness for any particular purpose The information in this document is subject to change without notice ABB assumes no responsibility for any errors that may appear in this document Mint is a registered trademark of Baldor a member of the ABB group Windows XP Windows Vista and Windows 7 are registered trademarks of the Microsoft Corporation UL and cUL are registered trademarks of Underwriters Labor...

Page 6: ...repair must not be attempted In the event that a drive fails to operate correctly contact the place of purchase for return instructions Precautions Do not touch any circuit board power device or electrical connection before you first ensure that no high voltage is present at this equipment or other equipment to which it is connected Electrical shock can cause serious or fatal injury Only qualified...

Page 7: ...he drive 2 1 1 Installation Before touching the option card be sure to discharge static electricity from your body and clothing by touching a grounded metal surface Alternatively wear an earth strap while handling the card 1 Choose carefully which of the option slots top or bottom to use The choice will often depend on the best route for the wiring that will lead to the option card 2 Pull off the ...

Page 8: ...licks into place The option card s external connector plate should finish approximately level with the 8 posts along the edge of the option slot 6 Insert the retaining screw and tighten If the screw will not locate in the threaded socket on the option card then check the position of the option card The screw must be fitted since it provides mechanical support and an electrical chassis connection f...

Page 9: ... bank 2 if the card is inserted in slot 2 The numbering of bank 1 slot 1 inputs and outputs always starts at 8 since 0 7 are reserved by bank 0 even though only AIN0 is used by a standard MotiFlex e100 The numbering of bank 2 slot 2 inputs and outputs always starts at 16 since 0 7 are taken by bank 0 and 8 15 are taken by bank 1 This numbering system is summarized in the following table and in Fig...

Page 10: ... AIN11 6 AIN10 7 AGND 8 AIN9 9 Shield 10 AGND 11 AIN8 12 13 NC 14 AGND 15 AOUT11 16 AOUT10 17 AGND 18 AIN11 19 AIN10 20 AGND 21 AIN9 22 Shield 23 AGND 24 AIN8 PCB this side NC 1 AGND 2 AOUT17 3 AOUT16 4 AGND 5 AIN19 6 AIN18 7 AGND 8 AIN17 9 Shield 10 AGND 11 AIN16 12 13 NC 14 AGND 15 AOUT19 16 AOUT18 17 AGND 18 AIN19 19 AIN18 20 AGND 21 AIN17 22 Shield 23 AGND 24 AIN16 PCB this side ...

Page 11: ...nput signal should be connected to the system using an individually shielded twisted pair cable with an overall shield The overall shield should be connected to the chassis at one end only No other connection should be made to the shield Figure 3 3 AIN8 16 analog input circuit When the MotiFlex e100 is connected to Mint WorkBench the analog input value expressed as a percentage can be viewed using...

Page 12: ...from an ABB NextMove e100 24 24 AIN8 16 ADC 8 ADC 16 AIN8 16 ADC 8 ADC 16 12 12 11 11 AIN8 16 AIN8 16 AIN8 16 GND Differential connection Single ended connection 24 AIN8 16 ADC 8 ADC 16 12 11 24 V DC 0 V 1 5kȍ 0 25 W 1kΩ 0 25 W potentiometer 24 1 12 2 11 3 OPT MF 001 Analog I O AIN8 16 AIN8 16 AGND AGND Demand0 Shield Connect overall shield at one end only NextMove e100 controller Analog out ...

Page 13: ...onnected to Mint WorkBench the analog output value expressed as a percentage can be viewed using the Spy window s Monitor tab The DAC command can be used in the command window to set the value of an analog output as a percentage of full scale For example assuming the card is mounted in slot 1 the command DAC 8 50 will set analog output 8 to 50 approximately 5 V See the Mint help file for details 3...

Page 14: ...3 6 Input Output MN1949WEN ...

Page 15: ...MN1949WEN Input Output 3 7 ...

Page 16: ...3 8 Input Output MN1949WEN ...

Page 17: ...et us know Write your comments in the space provided below remove this page from the manual and mail it to Manuals ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol BS32 0BF United Kingdom Alternatively you can e mail your comments to manuals uk baldor com Comment continued ...

Page 18: ...Comments MN1949WEN Thank you for taking the time to help us ...

Page 19: ......

Page 20: ...USA Telephone 262 785 3200 1 800 HELP 365 Fax 262 780 5135 www abb com drives ABB Beijing Drive Systems Co Ltd No 1 Block D A 10 Jiuxianqiao Beilu Chaoyang District Beijing P R China 100015 Telephone 86 10 5821 7788 Fax 86 10 5821 7618 www abb com drives ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol BS32 0BF United Kingdom Telephone 44 0 1454 850000 Fax 44 0 1454 859001 ...

Reviews: