4
GB
5
key, starting at step “l” it is increased by 1 step every 0,4
seconds. When setting “9” is reached the setting will not
be changed further (end stop). Ifthe selected cooking
zone will be switched ON by means of the MINUS key,
the cooking zone starts at the maximum setting “9”
(“reverse switching-ON”). When the key is continuously
operated, it decreases by 1 step every 0,4 seconds.
When setting “0” is reached, there will be no further
setting changed (end stop). Only arenewed operation
of the MINUS (or PLUS) key changes the setting.
Switching OFF an individuai cooking zone
To switch off an individual cooking zone, the respective
cooking zone has to be selected with the cooking-zone-
selectkey (= PLUS). The selection is indicated with the
static dot in the respective cooking zone display. If the
control recognizes that the PLUS (cooking-zone-select-
key is the PLUS-key) and the MINUS key have been
activated simultaneously the setting of the selected
cooking zone will be put back to “0”. Alternatively, the
MINUS-key can be used to count down the setting to
“0”. If all cooking zones are at “0”, all decimaI points
in the cooking zone displays are blinking. If a cooking
zone is “hof’, alternating “H” and “0”. When the sucepan
is removed, the zone switches to the wait mode for 10
minutes. The letter H and the symbol
alternate on
the display the cooking zone then switches off and the
letter H appears on the display.
Switching-OFF ali cooking zones:
Immediate switching-OFF of all cooking zones can be
achieved anytime by means of the ON/OFF key. In the
standby- mode an “H” appears on all cooking zones
which are “hot”. All other cooking zone displays are not
illuminated.
1.4 Power level
Cooking zone power can be adjusted to 9 levels,
indicated by the symbols “1” to “9” on the 7-segment
LED displays: The letter “P” on the display means that
the cooking zone is working at maximum power. The
letter “A” stands for automatic heating.
1.5 Pan sensor function
This activates automatically if a pan is not placed on
the cooking zone within 2.5 seconds from when it was
switched ono The symbol
appears on the display
1.6 Residual beat indicator
It is meant to indicate to the user that the glass ceramic
has a dangerous touch temperature in the circumference
of a cooking zone. The temperature will be determined
following a mathematical model and the remaining
residualheat will be indicated by means of “H” on the
corresponding 7-segment display. Heating-up and
Functions
1.1 Switching the Touch Control ON/OFF (Fig.2)
After mains voltage is applied the control initialised for
approx. 2.5-5 seconds before it is ready for operation.
After a reset all displays and LEDs gIow for approx. 1
second. When this time is over all displays and LEDs
extinguish and the controi is in the stand-by mode. By
operating the ON/OFF key the controi can be turned
into the ON-mode. The cooking zone displays show a
static “0”. If a cooking zone is in the “hot” status, the
display shows altemating “H” and “0”. The bottom right
dot is blinking in 1 second intervais on all cooking zone
displays to indicate that no cooking zone is selected at
the moment. After switching-ON the electronic control
remains activated for 20 seconds. If no cooking zone
or timer selection follows within this period of time, the
electronic control automatically switches back into the
stand-by-mode. The control can only be switched-ON
if it identifies the ON/OFF key alone being operated.
Should it recognize key activation other than that, the
control remains in the standby-mode. If the child safety
feature is active when switching on, all cooking zones
show “L”, (LOCKED). (also refer to 1.11). If the cooking
zones are in a “hot” status, the display shows “L” and
“H” in alternation. When the Touch Controi is ON it can
be switched-OFF at any time by operating the ON/OFF
key. This is aiso valid if the control has been Iocked
(activated child safety feature). The ON/OFF key has
always priority in the switch-OFF function.
1.2 Automatic switch-OFF
When the control is ON it automatically switches-OFF
after 20 seconds if no cooking zone or select key has
been operated within this period of time. If case of a
cooking zone selection, the automatic switch OFF
time is composed of 10 seconds deselection time for
a cooking zone at setting ”0” and 10 seconds switch-
OFF time.
1.3 Switching a cooking zone ON and OFF
If the control is ON the respective cooking zone can
be selected by operating a cooking-zone-select-key
(= PLUS-key of the respective cooking zone). There
is a static dot indication in the respective display. If
the cooking zone is hot “0”is displayed instead of
“H” .On all other cooking zone displays the blinking
dot extinguishes. Then a setting will be chosen by a
renewed operation of the cooking- zoneselect- key or
the MINUS-key and the cooking zone begins to heat
up. In order to use the cooking-zone-select-key as a
PLUS-key the controi has to recognize that after the
selection the cooking zone has been released for 0,3
seconds. After selection of a cooking zone the setting
can be increased by continously pressing the PLUS-