6
GB
7
and the switching off of the assigned Key-Lock warning
signal. All the sensor buttons can be once more
activated.
Pause Function
Activating the pause button you freeze the
absorptions of set adjustments.
Subsequent activation triggers the adjustments set
previously.
Automatic Heating (Or “Heat-Up” Function)
This function facilitates cooking. You don’t have to
be there permanently during cooking. The hob heats
up automatically to full power and then returns to the
selected level after a certain time (see table 1).
Activating Automatic Heating
1.
Press the selection button (2) for the desired
cooking area.
2.
Select power level 9 with the Minus
button, then use the Plus button to select level “A”
“9”. Afterwards set the desired level for continuation of
cooking with the Minus button, e.g. level 6. The display
will show alternatively “A” and “6” during the “automatic
heating” function.
Example: Select power level 9 and activate the
automatic heating function with the Plus button (display
9). Then set level 6 for continuation of cooking with the
Minus button. With these settings the hob will be heated
for 2.5 min. at level 9, the display will alternate “A” and
“6” and will then return to continuation cooking level 6.
TAB. 1
Power level
Heat-up function (Time in minutes)
1
1
2
3
3
4.8
4
6.5
5
8.5
6
2.5
7
3.5
8
4.5
9
---
is interrupted. Both the sound and visual signals of
the timer are deactivated.
• If confirmation of the alarm takes place by pressing a
button, the sound signal is deactivated immediately
and a button confirmation beep is emitted.
Depending on the moment of confirmation, the signal
of confirmation could coincide with the alarm sound
signal. In the case of alarm confirmation by means of
pressing a button, the actual function of the buttons
will not be carried out. To activate button function they
must be released and then reactivated.
• Exception: ON/OFF button: in the case of alarm
confirmation by means of the ON/OFF button, the alarm
signals will be deactivated 300 ms after activation. If
the button remains activated subsequently, the control
will switch to OFF mode after a total of 1 s.
• If the control was in the OFF mode (alarm clock), on
expiry of the time the control will remain in the OFF
mode. Only alarm confirmation is possible.
Switching Off The Timer/Modification Of Timer Settings
• The set value of the timer can be modified, in WAIT
or ACTIVE mode, at any time after selection has been
effected, which is to say directly in the alarm clock
mode by activating the Plus or Minus button.
• The timer can be switched off by taking it to the “00”
value, pressing the Minus button or simultaneously
pressing the Plus and Minus buttons once.
• Timers connected to the cooking areas are
deactivated when the cooking level in the assigned
cooking area is taken to 0.
Key Lock Locking/Activation
Pressing the Key-Lock button in WAIT or ACTIVE
mode locks the keyboard. The Key-Lock warning
light comes on in static mode. The time schedule must be
observed for activating the Key-Lock button. The control
goes on working in the previously set mode but cannot be
controlled with buttons other than the Key-Lock or ON/OFF
buttons. All the locked buttons are not commanded by the
control with regard to continuous activation. Switching off
with the ON/OFF button is also possible in the locked state.
The function Key-Lock, incl. control warning light, is again
active in the case of switching on again (in WAIT mode 10
s) until it is deactivated by once more depressing the Key-
Lock button. Activation/deactivation of the Key-Lock
function is not possible in the OFF mode. If programmed
timers should be in function, the respective timer alarms
must be confirmed by depressing any button whatever,
without having to unlock the control previously.
Key Lock Unlocking/Deactivation
The new activation of the Key-Lock button in the WAIT
or ACTIVE mode involves the unlocking of the keyboard
Summary of Contents for EMT 620 IX
Page 1: ...INSTRUCTION MANUAL EMT 620 IX EMT 720 IX ...
Page 2: ......
Page 9: ...GB 9 Fig 4 Fig 5 Considering contemporaneity factor ...
Page 19: ...DE 19 Abb 4 Abb 5 Bei Gleichzeitigkeitsfaktor ...
Page 29: ...NL 29 Afb 4 Afb 5 In aanmerking van de Geleijktijdigheidsfactor ...
Page 39: ...FR 39 Fig 4 Fig 5 En tenant compte du coefficient de simultaneité ...
Page 43: ......
Page 44: ...1 005 67 1 ...