background image

ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS                  page 3

Brochure # 083-3

32 Cross St, Brookvale, Sydney NSW 2100, Australia    Tel: (02) 99392844   Fax: (02) 99383462   Email: [email protected]

MOUNTING DETAILS

Coin Exit

TOP VIEW

OF 

VALIDATOR

Panel

Face 
Plate

33mm

140mm

90mm

45mm

25mm

Panel mounting is achieved by fitting the face plate
on one side of the panel and the validator on the
other.

Slip fitting is possible with the addition of a mounting
bracket to the bottom mounting screws. Screws
through this extra bracket are usually covered by a
cash box fascia.

PANEL CUT OUT DETAILS

1 to 1 Approximately

Summary of Contents for C22 Series

Page 1: ... 3462 International Tel 61 2 9939 2844 Fax 61 2 9938 3462 Email contact abberfield com au Internet www abberfield com au C22 DESIGNATES COIN VALIDATOR USING THE 22 SERIES PLASTIC MOULDINGS The information detailed is generic to cover the different validator types This literature primarily covers the C22P validators Suffixes may be added to cover specific applications More specific information is p...

Page 2: ... be automatically rejected In this way the range of coins to be accepted can be quickly set without needing to reprogramme the validator Note after changing a switch position turn the supply for the system off and then on to electronically reset the old switch positions Operation by 12 Volts A C or D C Inclusion of an inbuilt transformer to allow a primary supply voltage of the customer s choice 2...

Page 3: ...DETAILS Coin Exit TOP VIEW OF VALIDATOR Panel Face Plate 33mm 140mm 90mm 45mm 25mm Panel mounting is achieved by fitting the face plate on one side of the panel and the validator on the other Slip fitting is possible with the addition of a mounting bracket to the bottom mounting screws Screws through this extra bracket are usually covered by a cash box fascia PANEL CUT OUT DETAILS 1 to 1 Approxima...

Page 4: ...HNICAL DETAILS page 4 Brochure 083 3 32 Cross St Brookvale Sydney NSW 2100 Australia Tel 02 99392844 Fax 02 99383462 Email contact abberfield com au Using the SET and NEXT push buttons plus the 8 way dip switch located on the side of the coin validator in conjunction with the display it is possible to calibrate for any coin set This is normally a factory operation but it can be done by a skilled t...

Page 5: ... to the next coin parameter press the NEXT button 5 After all parameters for that coin have been displayed the screen will return to C1 C8 6 To advance to the next coin press the NEXT button 7 To display parameters for the coin press the SET button 8 Repeat steps 3 to 7 until all coins have been recorded 9 An overlap in all 3 parameters diameter period and amplitude between 2 or more coins will ca...

Page 6: ... price since the last resetting of the log data MAIN LOG TABLE 1 If the Audit Log input is shorted momentarily or kept shorted the display will show the normal data log with the omission of the Gross revenue PRICE ADJUSTMENT DATA RETRIEVAL AAAABB BB AAAABB BB 2 If the Audit Log input is shorted twice in one second then the display will show the full data log including the Gross revenue since the u...

Page 7: ...y screws one from each side of the unit They form one assembly covered by a single serial number PROCEDURE 1 Using a neat fitting bladed screwdriver remove the right hand plastic holding screw located under the ledge on the right side 2 Remove the identical left side screw located at the top of the left moulding 3 The two side mouldings are now free to slide off the middle fascia moulding They are...

Page 8: ...PUTS 12 to 24V AC or DC 11 10 12 bypass show car count Power off Set dip switches up Power on Display shows PAr Set dip switches down Push SET button PO on display price one Push SET button Current price one on display last digit flashing 00 0 To change push NEXT until new figure shown 0 to 9 Push SET next digit flashes 00 0 Repeat above for all digits Display returns to P0 Push NEXT for next pric...

Reviews: