SPECIFICATION

 

 

Up to 8 coins may be validated in the physical
range 16 mm to 32 mm diameter and
thickness to 3.5 mm. Coins are validated
optically for a diameter measurement and
washer detection, plus the rate of travel.
Resistivity and permeability measurements
are also taken for metal type verification.

 

 

Two tables of acceptance / rejection criteria
are included in the design (wide and narrow).
Selection is by a dip switch on the side of the
validator (accessed without tools) and in
normal operation the wide setting is used for
best acceptance of worn or damaged coins,
but in case of potential fraudulent use, the
narrow setting is easily engaged. 

 

 

Another switch engages the diagnostic
reporting function where any coin not
validated will momentarily show a code on the
display, indicating the reason for the failure to
validate, plus other codes for other fault
conditions. 

 

 

There are a further 6 dip switches that can be
used to invalidate the acceptance of different
coin denominations. These refer to the first 6
coins in the set up table (which usually covers
all those normally required). Switched to the
Validate positions coins will be accepted as
normal, but if any switch is in the Invalidate
position  that  coin  will be automatically
rejected. In this way the range of coins to be
accepted can be quickly set without needing
to reprogramme the validator. Note, after
changing a switch position turn the supply for
the system off and then on, to electronically
reset the old switch positions.

 

 

Operation by 12 Volts, A.C. or D.C.

 

 

Inclusion of an inbuilt transformer to allow a
primary supply voltage of the customer’s
choice (240V 50 cycles for Australia).

 

 

As an alternate to the isolation transformer a
solid state regulator can be fitted, allowing
operation of the validator on 24V A.C. or D.C.

 

 

4 relay output (with common line), contacts 
rated at 10 Amps on 240 Volts. These are
derated to 5 Amps for safety. If the contacts
are to be isolated from each other the number
of relays reduces, due to limitations on input
terminations.

 

 

4 optocoupler inputs that operate on a
nominal voltage of between 5 and 24 Volts
A.C. or D.C. (limits in the order of 2 to 30
Volts). These same optocouplers have
separate pin strip connection for a D.C.
sourcing current of approximately 3 - 30
milliAmps (LED input). On this pin strip there
are an additional 4 opto isolated inputs.

 

 

On the main plug in / screw connect terminal
block are two connections for audit require-
ments. Bridging these (external key switch,
etc...) causes the display to show the total of
coins since the system was installed, followed 
by the value of coins since the audit function
was last interrogated. (Refer to data retrieval
for full instructions).

 

 

It is possible to expand the validator /
controller to give up to four additional relay
outputs on two separate commons.

COIN VALIDATOR

C22 SERIES

70mm

140mm

Summary of Contents for C22 Series

Page 1: ... 3462 International Tel 61 2 9939 2844 Fax 61 2 9938 3462 Email contact abberfield com au Internet www abberfield com au C22 DESIGNATES COIN VALIDATOR USING THE 22 SERIES PLASTIC MOULDINGS The information detailed is generic to cover the different validator types This literature primarily covers the C22P validators Suffixes may be added to cover specific applications More specific information is p...

Page 2: ... be automatically rejected In this way the range of coins to be accepted can be quickly set without needing to reprogramme the validator Note after changing a switch position turn the supply for the system off and then on to electronically reset the old switch positions Operation by 12 Volts A C or D C Inclusion of an inbuilt transformer to allow a primary supply voltage of the customer s choice 2...

Page 3: ...DETAILS Coin Exit TOP VIEW OF VALIDATOR Panel Face Plate 33mm 140mm 90mm 45mm 25mm Panel mounting is achieved by fitting the face plate on one side of the panel and the validator on the other Slip fitting is possible with the addition of a mounting bracket to the bottom mounting screws Screws through this extra bracket are usually covered by a cash box fascia PANEL CUT OUT DETAILS 1 to 1 Approxima...

Page 4: ...HNICAL DETAILS page 4 Brochure 083 3 32 Cross St Brookvale Sydney NSW 2100 Australia Tel 02 99392844 Fax 02 99383462 Email contact abberfield com au Using the SET and NEXT push buttons plus the 8 way dip switch located on the side of the coin validator in conjunction with the display it is possible to calibrate for any coin set This is normally a factory operation but it can be done by a skilled t...

Page 5: ... to the next coin parameter press the NEXT button 5 After all parameters for that coin have been displayed the screen will return to C1 C8 6 To advance to the next coin press the NEXT button 7 To display parameters for the coin press the SET button 8 Repeat steps 3 to 7 until all coins have been recorded 9 An overlap in all 3 parameters diameter period and amplitude between 2 or more coins will ca...

Page 6: ... price since the last resetting of the log data MAIN LOG TABLE 1 If the Audit Log input is shorted momentarily or kept shorted the display will show the normal data log with the omission of the Gross revenue PRICE ADJUSTMENT DATA RETRIEVAL AAAABB BB AAAABB BB 2 If the Audit Log input is shorted twice in one second then the display will show the full data log including the Gross revenue since the u...

Page 7: ...y screws one from each side of the unit They form one assembly covered by a single serial number PROCEDURE 1 Using a neat fitting bladed screwdriver remove the right hand plastic holding screw located under the ledge on the right side 2 Remove the identical left side screw located at the top of the left moulding 3 The two side mouldings are now free to slide off the middle fascia moulding They are...

Page 8: ...PUTS 12 to 24V AC or DC 11 10 12 bypass show car count Power off Set dip switches up Power on Display shows PAr Set dip switches down Push SET button PO on display price one Push SET button Current price one on display last digit flashing 00 0 To change push NEXT until new figure shown 0 to 9 Push SET next digit flashes 00 0 Repeat above for all digits Display returns to P0 Push NEXT for next pric...