TO PROGRAM COPY PRICES
1.
Remove supply power to the validator.
2.
Locate Dip Switches and Push Buttons and
set all Dip Switches to UP (or ELIMINATE)
3.
Turn supply power back on.
4.
While Display is scrolling though
“ABBERFIELD” etc. Set all Dip Switches to
DOWN (or VALIDATE) position.
5.
When Display shows “PAR” press SET
button once so that display now shws “P0”.
6.
P 0 is price #1.
7.
To change this price push the 'SET' push
button again.
8.
The display will then show the current price
for this price with the last digit flashing 00. 0
9.
To change this digit push the 'SET' push
button until the desired figure is shown, 0 to 9.
10.
To change another digit push the 'SET' push
button until the desired digit is flashing.
11.
Then push the 'NEXT' push button to change
its value.
12.
Once you have stepped through all 4 digits
then the display will read 'PO'
13.
Again, to advance to the next price push the
'NEXT' push button until the desired price
position is reached.
14.
PO to P5 are the price positions for prices 1
to 6.
15.
To change all the prices repeat above
procedure.
16. Do not change P6 to P9 unless instructed
by the manufacturer.
17.
Once all the prices you desire the validator to
work on have been set, turn the validator off
and then return the dip switches to their
normal position, (usually all down). Then turn
the power back on.
A data retrieval mode allows the unit to display the
number of operations at each price since the last
resetting of the log data.
MAIN LOG TABLE
1.
If the Audit Log input is shorted momentarily
or kept shorted, the display will show the
normal data log with the omission of the Gross
revenue.
PRICE ADJUSTMENT
DATA RETRIEVAL
$AAAABB.BB
$AAAABB.BB
2.
If the Audit Log input is shorted twice in one
second then the display will show the full data
log including the Gross revenue since the unit
was installed.
Display
Function
Log 1
Main log number (increments in
reset)
t0t
Total revenue since last data reset in
the format.
AAAA
BB.BB
GrOS
Gross revenue since installation in
the format
AAAA
BB.BB
vv.vv
Price (if not set to zero)
n
Number of operations at price vv.vv
vv.vv and n repeats until all prices f o r
the application have been displayed.
End
RESET MAIN LOG TABLE
When the display shows 'End' if the Audit log input
is shorted again more than 2 seconds then the
total revenue and the number of operations for
each price are reset to zero. The display will show
'rSt' acknowledging that the log data was reset.
The log number will be incremented to next value.
The short should be removed whilst the display
shows ‘rSt’.
NOTE: If the coin validator By-Pass inputs are
energised and the Audit Log input is shorted as for
normal data retrieval the log of the free operations
will be displayed.
OPERATING PARAMETERS
The validators have a number of other adjustments
that can be field adjusted, such as the length of
time of the output relay pulse. These adjustment
are application specific and may therefore have a
different effect on each type of unit.
In this regard even the price adjustment procedure
may vary between unit types and details should be
attached to the side of the coin validator.
For clarity on these matters please refer to
Abberfield Industries technical support.