ABBERFIELD INDUSTRIES - C22 coin validators TECHNICAL DETAILS                  page 6

Brochure # 083-3

32 Cross St, Brookvale, Sydney NSW 2100, Australia    Tel: (02) 99392844   Fax: (02) 99383462   Email: [email protected]

TO PROGRAM COPY PRICES

1.     

Remove supply power to the validator.

2.

Locate Dip Switches and Push Buttons and

set all Dip Switches to UP (or ELIMINATE)

3.

Turn supply power back on.

4.

While Display is scrolling though 

“ABBERFIELD” etc. Set all Dip Switches to 

DOWN (or VALIDATE) position.

5.

When Display shows “PAR” press SET 
button once so that display now shws “P0”.

6.

P 0 is price #1.

7.

To change this price push the 'SET' push
button again.

8.

The display will then show the current price
for this price with the last digit flashing 00. 0

9.

To change this digit push the 'SET' push
button until the desired figure is shown, 0 to 9.

10.

To change another digit push the 'SET' push
button until the desired digit is flashing.

11.

Then push the 'NEXT' push button to change
its value.

12.

Once you have stepped through all 4 digits
then the display will read 'PO'

13.

Again, to advance to the next price push the
'NEXT' push button until the desired price
position is reached.

14.

PO to P5 are the price positions for prices 1
to 6.

15.

To change all the prices repeat above
procedure.

16. Do not change P6 to P9 unless instructed

by the manufacturer.

17.

Once all the prices you desire the validator to
work on have been set, turn the validator off
and then return the dip switches to their
normal position, (usually all down). Then turn
the power back on.

A data retrieval mode allows the unit to display the
number of operations at each price since the last
resetting of the log data.

MAIN LOG TABLE

1.

If the Audit Log input is shorted  momentarily
or kept shorted, the display will show the
normal data log with the omission of the Gross
revenue.

PRICE ADJUSTMENT

DATA RETRIEVAL

$AAAABB.BB

$AAAABB.BB

2.

If the Audit Log input is shorted twice in one
second then the display will show the full data
log including the Gross revenue since the unit
was installed.

Display

Function

Log 1

Main log number (increments in 
reset)

t0t

Total revenue since last data reset in 
the format.

AAAA

BB.BB

GrOS

Gross revenue since installation in 
the format

AAAA

BB.BB

vv.vv

Price (if not set to zero)

n

Number of operations at price vv.vv

vv.vv and n repeats until all prices  f o r
the application have been displayed.

End

RESET MAIN LOG TABLE

When the display shows 'End' if the Audit log input
is shorted again more than 2 seconds then the
total revenue and the number of operations for
each price are reset to zero. The display will show
'rSt' acknowledging that the log data was reset.
The log number will be incremented to next value.
The short should be removed whilst the display
shows ‘rSt’.
NOTE: If the coin validator By-Pass inputs are
energised and the Audit Log input is shorted as for
normal data retrieval the log of the free operations
will be displayed.

OPERATING PARAMETERS

The validators have a number of other adjustments
that can be field adjusted, such as the length of
time of the output relay pulse. These adjustment
are application specific and may therefore have a
different effect on each type of unit.

In this regard even the price adjustment procedure
may vary between unit types and details should be
attached to the side of the coin validator.

For clarity on these matters please refer to
Abberfield Industries technical support.

Summary of Contents for C22 Series

Page 1: ... 3462 International Tel 61 2 9939 2844 Fax 61 2 9938 3462 Email contact abberfield com au Internet www abberfield com au C22 DESIGNATES COIN VALIDATOR USING THE 22 SERIES PLASTIC MOULDINGS The information detailed is generic to cover the different validator types This literature primarily covers the C22P validators Suffixes may be added to cover specific applications More specific information is p...

Page 2: ... be automatically rejected In this way the range of coins to be accepted can be quickly set without needing to reprogramme the validator Note after changing a switch position turn the supply for the system off and then on to electronically reset the old switch positions Operation by 12 Volts A C or D C Inclusion of an inbuilt transformer to allow a primary supply voltage of the customer s choice 2...

Page 3: ...DETAILS Coin Exit TOP VIEW OF VALIDATOR Panel Face Plate 33mm 140mm 90mm 45mm 25mm Panel mounting is achieved by fitting the face plate on one side of the panel and the validator on the other Slip fitting is possible with the addition of a mounting bracket to the bottom mounting screws Screws through this extra bracket are usually covered by a cash box fascia PANEL CUT OUT DETAILS 1 to 1 Approxima...

Page 4: ...HNICAL DETAILS page 4 Brochure 083 3 32 Cross St Brookvale Sydney NSW 2100 Australia Tel 02 99392844 Fax 02 99383462 Email contact abberfield com au Using the SET and NEXT push buttons plus the 8 way dip switch located on the side of the coin validator in conjunction with the display it is possible to calibrate for any coin set This is normally a factory operation but it can be done by a skilled t...

Page 5: ... to the next coin parameter press the NEXT button 5 After all parameters for that coin have been displayed the screen will return to C1 C8 6 To advance to the next coin press the NEXT button 7 To display parameters for the coin press the SET button 8 Repeat steps 3 to 7 until all coins have been recorded 9 An overlap in all 3 parameters diameter period and amplitude between 2 or more coins will ca...

Page 6: ... price since the last resetting of the log data MAIN LOG TABLE 1 If the Audit Log input is shorted momentarily or kept shorted the display will show the normal data log with the omission of the Gross revenue PRICE ADJUSTMENT DATA RETRIEVAL AAAABB BB AAAABB BB 2 If the Audit Log input is shorted twice in one second then the display will show the full data log including the Gross revenue since the u...

Page 7: ...y screws one from each side of the unit They form one assembly covered by a single serial number PROCEDURE 1 Using a neat fitting bladed screwdriver remove the right hand plastic holding screw located under the ledge on the right side 2 Remove the identical left side screw located at the top of the left moulding 3 The two side mouldings are now free to slide off the middle fascia moulding They are...

Page 8: ...PUTS 12 to 24V AC or DC 11 10 12 bypass show car count Power off Set dip switches up Power on Display shows PAr Set dip switches down Push SET button PO on display price one Push SET button Current price one on display last digit flashing 00 0 To change push NEXT until new figure shown 0 to 9 Push SET next digit flashes 00 0 Repeat above for all digits Display returns to P0 Push NEXT for next pric...

Reviews: